| поискавой системы для электроныых деталей |
|
INA238 датащи(PDF) 20 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
INA238 датащи(HTML) 20 Page - Texas Instruments |
|
20 / 49 page ![]() Frame 1 Two-Wire Secondary Address Byte (1) Frame 2 Register Pointer Byte 1 Start By Main ACK By Secondary ACK By Secondary 1 9 1 9 SDA SCL 0 0 A3 A2 A1 A0 R/W P7 P6 P5 P4 P3 P2 P1 P0 Stop ¢ A. The value of the Secondary Device Address Byte is determined by the settings of the A0 and A1 pins. Refer to Table 7-2. Figure 7-9. Typical Register Pointer Set 7.5.1.2 High-Speed I2C Mode When the bus is idle, both the SDA and SCL lines are pulled high by the pullup resistors. The main device generates a start condition followed by a valid serial byte containing high-speed (HS) main device code 00001XXX. This transmission is made in fast (400 kHz) or standard (100 kHz) (F/S) mode at no more than 400 kHz. The device does not acknowledge the HS main device code, but does recognize it and switches its internal filters to support 2.94-MHz operation. The main device then generates a repeated start condition (a repeated start condition has the same timing as the start condition). After this repeated start condition, the protocol is the same as F/S mode, except that transmission speeds up to 2.94 MHz are allowed. Instead of using a stop condition, use repeated start conditions to maintain the bus in HS-mode. A stop condition ends the HS-mode and switches all the internal filters of the device to support the F/S mode. 7.5.1.3 SMBus Alert Response The INA238 is designed to respond to the SMBus Alert Response address. The SMBus Alert Response provides a quick fault identification for simple secondary devices. When an Alert occurs, the main device can broadcast the Alert Response secondary device address (0001 100) with the Read/Write bit set high. Following this Alert Response, any secondary device that generates an alert identifies itself by acknowledging the Alert Response and sending its address on the bus. The Alert Response can activate several different slave devices simultaneously, similar to the I2C General Call. If more than one slave attempts to respond, bus arbitration rules apply. The losing device does not generate an Acknowledge and continues to hold the Alert line low until that device wins arbitration. 7.6 Register Maps 7.6.1 INA238 Registers Table 7-3 lists the INA238 registers. All register locations not listed in Table 7-3 should be considered as reserved locations and the register contents should not be modified. Table 7-3. INA238 Registers Address Acronym Register Name Register Size (bits) Section 0h CONFIG Configuration 16 Go 1h ADC_CONFIG ADC Configuration 16 Go 2h SHUNT_CAL Shunt Calibration 16 Go 4h VSHUNT Shunt Voltage Measurement 16 Go 5h VBUS Bus Voltage Measurement 16 Go 6h DIETEMP Temperature Measurement 16 Go 7h CURRENT Current Result 16 Go 8h POWER Power Result 24 Go Bh DIAG_ALRT Diagnostic Flags and Alert 16 Go Ch SOVL Shunt Overvoltage Threshold 16 Go INA238 SLYS025 – JANUARY 2021 www.ti.com 20 Submit Document Feedback Copyright © 2021 Texas Instruments Incorporated Product Folder Links: INA238 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |