| поискавой системы для электроныых деталей |
|
ZSSC3240CC1B датащи(PDF) 21 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
ZSSC3240CC1B датащи(HTML) 21 Page - Renesas Technology Corp |
|
21 / 64 page ![]() ZSSC3240 Datasheet Nov.27.20 Page 21 Application Front-End Configuration, Temperature Sensor Application, and Connection Circuit Setup and Comments T4 PGA VTP VTN Internal Temp. Sensor TEXT Rt´ Rt extr a_rt INP INN VSSB VDDB Sensor Element Sensor Bias Current Rsens Regulated Voltage, VDDA Vsup Temperature sensor with internal Rt with ratiometric supply Sensor element supplied through the ZSSC3240- internal regulated voltage VDDA, i.e. radiometric supply temp_source = 101 BIN internal_rt = User selected extra_rt = 0 BIN Note: Only combine this T4 application with sensor_sup = 00BIN (i.e., main sensing application S1 in Table 13) T5 PGA VTP VTN Internal Temp. Sensor TEXT Rt´ Rt extr a_rt INP INN VSSB VDDB Sensor Element Rsens Regulated Voltage, VDDA Rt,external Sensor Bias Current Temperature Sensor with external Rt with ratiometric supply Sensor element supplied through the ZSSC3240- internal regulated voltage VDDA; i.e., the radiometric supply temp_source = 110 BIN internal_rt = any value close to the external Rt value extra_rt = 0 BIN Note: Only combine this T5 application with sensor_sup = 00BIN only (i.e., main sensing application S1 in Table 13) When using scenario T1, “Bridge as the temperature sensor with the internal Rt in Current Mode” in Table 15, the setup for bias current (Isup) and internal Rt must fulfill the requirements given in Equation 4 and Equation 5: (0.5 R sens + Rt) I sup = 0.85V ±125mV Equation 4 Where Rsens is the nominal resistance of the sensor element; i.e. the typical, effective resistance generating the differential sensor signal as input to the INP and INN pads. Important: Take into consideration the maximum specifications for the PGA common mode input level, VCmin (see Table 4). (MAX[Rsens ] – MIN[Rsens]) I sup < 700mV Equation 5 Important: Take into consideration the maximum specifications for the input signal, MAX[VDIFFin] (see Table 4). The best method for deriving the respective values for Rt and Isup is to choose an Rt value close to but greater than Rsens and to calculate Isup accordingly. When using scenario T4, “Temperature sensor with internal Rt with ratiometric supply,” in Table 15 the setup for bias current (Isup) and internal Rt must fulfill Equation 6: Important: Take into consideration the maximum specifications for the PGA common mode input level, VCmin, which is automatically ensured if Rt and the extra Rt ’ are selected. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |