| поискавой системы для электроныых деталей |
|
TLE4943C датащи(PDF) 32 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
TLE4943C датащи(HTML) 32 Page - Infineon Technologies AG |
|
32 / 48 page ![]() TLE4943C Data Sheet 32 V 1.2, July 2018 3.3 Operating Range All parameters specified in the following sections refer to these operating conditions unless otherwise noticed. Table 5 Operating Range Parameter Symbol Values Unit Note / Test Condition Min. Typ. Max. Supply voltage V DD 6.5 – 20 V Directly on IC leads; does not include voltage drop at RM VDD Hysteresis Vres 4.0V 4.2 4.5 V AK: reset voltage Vhys 1.6 1.8 2.3 Vrel 5.8 6.5 AK: return voltage Supply voltage modulation V AC 6 V pp V DD=13V; 0<f mod<150kHz 1) 1) sine wave Junction temperature Tj Either -40 110 °C 12500h2) 2) This lifetime statement is an anticipation based on an extrapolation of Infineon's qualification test results. The actual lifetime of a component depends on its form of ap plication and type of use etc. and may deviate from such statement. The lifetime statement shall in no event extend the agreed warranty period. OR 125 10000h2) OR 150 5000h OR 160 2500h OR 170 500h Pre induction B o -500 500 mT Temperature change per magnetic period for valid DR dTj_Dir -7.5 7.5 K 3) valid for dB dir > 1.9mT 3) The permissible change of the temperature is, e.g. 7.5K per one magnetic periode. For example a magnetic signal of 10Hz (Tmag = 0.1s) results in a max change of temperature = 7.5K / 0.1s = 75K / s. A wrong direction info may occure if dTj_Dir is exceeded. Temperature change at standsill dTj_Speed -150 50 K 4)valid for dB > 3mT 4) More than 2 speed protocols might be lost if the temperature change during standstill is exceeded at re-drive. Pre induction offset between outer probes B stat l/r -30 30 mT Differential induction dB -120 120 mT Pre-induction offset between mean of outer probes and center probe B stat m/o -30 30 mT Signal frequency f 050005) 5) 5000Hz electric signal frequency are equal to 2500Hz magnetic signal frequency (one sin period has two increments). Hz Minimum magn. frequency for direction detection f dir_min 0.54 0.66 0.83 Hz |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |