| поискавой системы для электроныых деталей |
|
UBX-15025564-R16 датащи(PDF) 14 Page - u-blox AG |
|
|
|||||||||||||||||||||||||||||
UBX-15025564-R16 датащи(HTML) 14 Page - u-blox AG |
|
14 / 30 page ![]() SARA-N2 series - Data Sheet UBX-15025564 - R16 Electrical specification Page 14 of 30 4 Electrical specification ⚠ Stressing the device above one or more of the ratings listed in the Absolute Maximum Rating section may cause permanent damage. These are stress ratings only. Operating the module at these or at any conditions other than those specified in the Operating Conditions section (section 4.2) of the specification should be avoided. Exposure to Absolute Maximum Rating conditions for extended periods may affect device reliability. ☞ Operating condition ranges define those limits within which the functionality of the device is guaranteed. ☞ Electrical characteristics are defined according to the verification on a representative number of samples or according to the simulation. ☞ Where application information is given, it is advisory only and does not form part of the specification. 4.1 Absolute maximum rating ☞ Limiting values given below are in accordance with the Absolute Maximum Rating System (IEC 134). Symbol Description Condition Min. Max. Unit VCC Module supply voltage Input DC voltage at VCC pin 4.25 V GDI Generic digital interfaces Input DC voltage at Generic digital interfaces pins 2.1 V SIM SIM interface Input DC voltage at SIM interface pins 2.1 V UART UART interface Input DC voltage at UART interface pins 4.25 V ERS External reset signal Input DC voltage at RESET_N pin 4.25 V Rho_ANT Antenna ruggedness Output RF load mismatch ruggedness at ANT pins 10:1 VSWR Tstg Storage temperature -40 85 °C Table 6: Absolute maximum ratings ⚠ The product is not protected against overvoltage or reversed voltages. If necessary, voltage spikes exceeding the power supply voltage specification given in table above must be limited to values within the specified boundaries by using appropriate protection devices. 4.1.1 Maximum ESD Parameter Min Typical Max Unit Remarks ESD sensitivity for all pins 1000 V Human Body Model according to JESD22-A114 Table 7: Maximum ESD ratings ⚠ u-blox cellular modules are Electrostatic Sensitive Devices and require special precautions when handling. See section 7.4 for ESD handling instructions. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |