| поискавой системы для электроныых деталей |
|
VR13 датащи(PDF) 5 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
VR13 датащи(HTML) 5 Page - Infineon Technologies AG |
|
5 / 20 page ![]() PXE1610C PDS-PXE1-PXM1-C-001A 5 Pin # Name I/O Type Description 11 AVRRDY O Open Drain Voltage regulator “Ready” output signal. The AVRRDY indicator will be asserted when the controller is ready to accept SVID commands after AVREN is asserted. This open-drain output requires an external pull-up resistor (1k recommended). AVRRDY will be pulled low when a shutdown fault occurs. 12 AVREN I 1.2V CMOS Note G Active high Output Enable input. Asserting the AVREN pin will activate the digital controller, pending status of the internal power-on-reset circuit and any existing fault states. De-asserting then asserting AVREN after a latched- fault based shutdown will cause the controller to enter the soft-start state. Faults will be cleared when AVREN is reasserted. 13 VRHOT# O Open Drain Active low external temperature indicator. VRHOT# is asserted at the temperature defined by the programmable TEMP_MAX register. 14 PINALRT# O Open Drain Active low external input supply power alert. PINALRT# is asserted when the input power reaches the threshold defined by the programmable PIN_MAX register. Unused PINALRT# may be left open. 15 MP0 I/O Note D Multi-purpose pin-0 configurable as BVRRDY, FAULT1, FAULT2, ADREN, BDREN, or LPM; Unused MP pins may be left open. Note C. Note F 16 MP1 I/O Note D Multi-purpose pin-1 configurable as BVREN, BVRRDY, FAULT1, FAULT2, ADREN, BDREN, or SMBAlert#; Note C. Note F 17 VCLK I 1.2V CMOS SVID clock interface. Note E 18 VDIO I/O Open Drain SVID bi-directional data interface. Note E 19 VALRT# O Open Drain SVID active low ALERT# signal. This output is asserted to indicate the status of the VR has changed. Note E 20 MP2 I/O Note D Multi-purpose pin-2 configurable as FAULT2, SMBAlert#, or IMON. Note F 21 AVSEN I Analog Loop_A voltage sense inputs. AVSEN (+) and AVREF (-) are inputs to the precision differential remote sense amplifier and should be connected to the sense pins of the remote load. To attenuate high frequency noise coupled onto the sense lines, it is recommended that an RC filter (10Ω and 220pF) be placed close to the controller. 22 AVREF I Analog 23 AIREF1 I Analog Loop_A phase #1 current sense inputs. The AIREF1 (-) and AISEN1 (+) pins are used to differentially sense the corresponding channel current. The sensed current is used for channel-to-channel current balancing, loadline regulation, and over-current protection. Unused AIREFx/AISENx pins may be left open or tied to ground. 24 AISEN1 I Analog 25 AIREF2 I Analog Loop_A phase #2 current sense inputs. Refer to AIREF1/AISEN1 description. 26 AISEN2 I Analog 27 AIREF3 I Analog Loop_A phase #3 current sense inputs. Refer to AIREF1/AISEN1 description 28 AISEN3 I Analog 29 AIREF4 I Analog Loop_A phase #4 current sense inputs. Refer to AIREF1/AISEN1 description 30 AISEN4 I Analog 31 AIREF5 I Analog Loop_A phase #5 current sense inputs. Refer to AIREF1/AISEN1 description 32 AISEN5 I Analog 33 AIREF6 I Analog Loop_A phase #6 current sense inputs. Refer to AIREF1/AISEN1 description 34 AISEN6 I Analog |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |