| поискавой системы для электроныых деталей |
|
TLE5014 датащи(PDF) 20 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
TLE5014 датащи(HTML) 20 Page - Infineon Technologies AG |
|
20 / 45 page ![]() Final Datasheet 20 Rev. 1.0 2018-04-04 TLE5014 Specification 3.3.3 Angle Performance After internal angle calculation, the sensor has a remaining error, as shown in Table 3-11 for an ambient temperature range up to 85°C and a reduced magnetic field range and in Table 3-12 for the ambient temperature range up to 125°C and full magnetic operating range. The error value refers to BZ= 0mT. The overall angle error represents the relative angle error. This error describes the deviation from the reference line after zero-angle definition. It is valid for a static magnetic field. If the magnetic field is rotating during the measurement, an additional propagation error is caused by the angle delay time (see Table 3-9). Table 3-11 Angle Error for -40°C < TA < 85°C and magnetic field range 33mT < B < 50mT Parameter Symbol Values Unit Note / Test Condition Min. Typ. Max. Accuracy1) over temperature w/o look-up table 1) Hysteresis and noise are included in the angle accuracy specification AErr,T 0.8 ° 0h2), over temperature 2) “0h” is the condition when the part leaves the production at Infineon Accuracy1) over temperature and lifetime, w/o look-up table AErr,s 0.9 ° lifetime stress: TA=85°C/1000h/50mT Accuracy1)3) over temperature and lifetime, with look-up table 3) Verified by characterization AErr,sLUT 0.65 ° lifetime stress: TA=85°C/1000h/50mT with look-up table correction Hysteresis4) 4) Hysteresis is the maximum difference of the angle value for forward and backward rotation AHyst 0.1 0.16 ° value includes quantization error of 12bit angle output Table 3-12 Angle Error for -40°C < TA < 125°C Parameter Symbol Values Unit Note / Test Condition Min. Typ. Max. Accuracy1) over temperature w/o look-up table 1) Hysteresis and noise are included in the angle accuracy specification AErr,T 0.8 ° 0h2), over temperature B = 33mT to 80mT3) 2) “0h” is the condition when the part leaves the production at Infineon 3) For the magnetic field range of 25mT < B < 33mT, 0.2° have to be added to the max. angle accuracy Accuracy1) over temperature and lifetime, w/o look-up table AErr,s 1.0 ° 33mT…80mT3) lifetime stress: TA=125°C/2000h Accuracy1)4) over temperature and lifetime, with look-up table 4) Verified by characterization AErr,sLUT 0.85 ° B = 33mT to 80mT3), lifetime stress: TA=125°C/2000h with look-up table correction Hysteresis5) AHyst 0.1 0.16 ° B = 33mT to 80mT6), value includes quantization error of 12bit angle output |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |