| поискавой системы для электроныых деталей |
|
7534 датащи(PDF) 29 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
7534 датащи(HTML) 29 Page - Renesas Technology Corp |
|
29 / 55 page ![]() 7534 Group Rev.2.00 Jun 21, 2004 page 29 of 54 REJ03B0099-0200Z Note on using USB mode Handling of SE0 signal in program (at receiving) 7534 group has the border line to detect as USB RESET or EOP (End of Packet) on the width of SE0 (Single Ended 0). A response apposite to a state of the device is expected. The name of the following short words which is used in table 5 shows as follow. •TKNE: Token interrupt enable (bit 6 of address 2016) •RSME: Resume interrupt enable (bit 5 of address 2016) •RSTE: USB reset interrupt enable (bit 4 of address 2016) •Spec: A response of the device requested by USB Specification 1.1 •SIE: Hardware operation in 7534 group •F/W: Recommendation process in the program •FEOPE: False EOP error flag (bit 2 of address 1916) •RxPID: Token interrupt flag (bit 7 of address 1F16) Spec SIE F/W Reset or resume Reset interrupt request Reset interrupt processing Resume interrupt processing Table 5 Relation of the width of SE0 and the state of the device Width of SE0 0 µ s 0.5 µ s 0.5 µ s 2.5 µ s 2.5 µ s 2.67 µ s 2.67 µ s Spec SIE F/W Spec SIE F/W Spec SIE F/W Spec SIE F/W Idle state TKNE = X RSME = 0 RSTE =1 Ignore Keep counting suspend timer Not acknowledge Keep alive Initialize suspend timer count value Not acknowledge Keep alive or Reset may determine as keep alive and Reset interrupt Keep alive in case of no interrupt request Reset processing in case of interrupt request Reset Reset interrupt request Reset processing End of Token in transaction TKNE = 1 RSME = 0 RSTE =1 Ignore Not detected as EOP(in case of no detection EOP, SIE returns idle state as time out. FEOPE flag is set.) Not acknowledge EOP Token interrupt request Token interrupt processing execute EOP or Reset may determine as EOP and Reset interrupt RxPID = 1> Token interrupt processing RxPID = 0> Reset interrupt processing Reset Reset interrupt request Reset processing End of data or handshake in transaction TKNE = 0 RSME = 0 RSTE = 0 or 1 Ignore Not detected as EOP(in case of no detection EOP, SIE returns idle state as timeup. FEOPE flag is set.) Wait for the next EOP flag EOP Set EOP flag After checking the set of EOP flag, go to the next processing EOP or Reset may determine as EOP and Reset interrupt Continue the processing in case of no interrupt request Reset processing in case of interrupt request Reset Reset interrupt request Reset processing Suspend state TKNE = 0 RSME = 1 RSTE = 0 State of device • Function of USBPID control register 0 (address 002316) Bit 4 (STALL handshake control for OUT token) of this register is forcibly set by SIE under the special condition shown below. Set condition; when PID of data packet = DATA0 (incorrect PID) in the status stage of the control read transfer. • SYNC field at reception Normally, the SYNC field consists of “KJKJKJKK” (8 bits). However, as for SIE of the 7534 Group, when the low-order 6 bits are “KJKJKK”, it is determined as SYNC. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |