9 / 22 page ![]() TE0701 TRM v.66 Copyright © 2018 Trenz Electronic GmbH 9 of 22 http://www.trenz-electronic.de Green LED D22 indicates presence of 3.3V power from the SoM attached. 3.6 4-bit DIP-switch S3 There is a 4-bit DIP-switch S3 with following default settings: Switc h Functionality S3-1 CM1: Mode pin 1 (routed to System Controller CPLD). S3-2 CM0: Mode pin 0 (routed to System Controller CPLD). S3-3 JTAGEN: Set to ON for normal JTAG operation. Has to be set to OFF position for System Controller CPLD JTAG access. S3-4 MIO0: Pin from/to JB1-88 and PMOD (J1) connector. Direction depends on Module FPGA/ SoC configuration. Table 1: DIP-switch S3 settings. 3.7 User Push-buttons On the TE0701 Carrier Board there are two push-buttons (S1 and S2) and are routed to the System Controller CPLD and available to the user. The default mapping of the push-buttons is as follows: Nam e Default Mapping: S1 Custom Button functionality CPLD Firmware dependent. S2 If S2 is pushed, the active-high Power ON (PON) signal (that is internally pulled-up) will be de-asserted, which can be considered as a "RESTART" function as all on-module power supplies will be switched off (except 3.3VIN) on button push and back on again on button release. The active-high PON signal is directly mapped to the active-high EN1 signal which is routed to the module's System Controller CPLD (e.g., on the TE0720) and directly used as a mandatory active-high enable signal to the power FET switch, enabling on-module 3.3V power supply output as well as all other DC-DC converters on the module. Table 2: Description of default functions of user push-buttons S1 and S2. The function of the push-buttons depend on the System Controller CPLD firmware. For detailed information of the function of the push-buttons, please refer to the documentation of the TE0701 System Controller CPLD. LED5 (D5) to LED8 (D8) are operating only when the corresponding power supply VIOTB (i.e., bank 1 of the on-board System Controller CPLD) is switched on. This can be accomplished by connecting the FMC power supply FMC_VADJ to VIOTB (J21: 1,2-3), which is the default option, or by connecting either 2.5V (J17: 1, 2-3) or 3.3V (J17: 1-2,3) to VIOTB (J21: 1-2,3). Please note that for the first default option, the FMC power supply voltage must be set by the user. For detailed information how to set the voltage FMC_VADJ via I2C, please refer to the documentation of the TE0701 System Controller CPLD. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |