| поискавой системы для электроныых деталей |
|
PCF7936AS датащи(PDF) 24 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
PCF7936AS датащи(HTML) 24 Page - NXP Semiconductors |
|
24 / 32 page ![]() NXP Semiconductors Product Specification Security Transponder (HITAG2) PCF7936AS 2010 May 04 24 CONFIDENTIAL 7.7 LF Field Power On Reset When the transponder enters a LF field a rectifier circuitry becomes operational and the internal transponder supply voltage (VDD) develops. As soon as the supply voltage exceeds the LF Field Power-On Reset threshold voltage (VTHR) the device performs a chip reset and starts its initialization sequence, see Figure 23. Subsequently, the transponder is muted and does not respond to any command prior to termination of the initialization sequence, tINIT. The startup time, tSTART, depends on the basestation configuration, the resonance circuit properties and the system coupling factor, however, is small compared with the initialization time typically. For proper device operation, after a LF Filed Power-On Reset condition, command execution must commence within the specified Idle time, tIDLE, see Figure 23. Otherwise the device may stop command decoding, disabling any communication with the device. In this case a LF Field Power-On Reset has to be applied, in order to reset and initialize the circuitry. Consequently, the device would resume WAIT state. As indicated, the Idle time is specified as the time interval following the initialization sequence until the last bit of the Command Sequence that is send to the transponder. In case one of the Read Only modes is enabled, the device enters READ ONLY state, if the first two bits of the START_AUTH command are not being recognized within the time-out period tWAIT,SA. In this case, Read Only operation commences tWAIT,RO after termination of the initialization sequence, tINIT, see Figure 23. For details refer to section 7.5. In order to force a LF Field Power-On Reset and proper device initialization at any time, the LF field OFF condition must be applied for at least tRESET,SETUP, in order to ensure that the internal device supply voltage, VDD, drops below the threshold voltage (VTHR), see Figure 24. LF field applied VTHR tINIT VDD tSTART LF field power on reset (POR) threshold voltage t tIDLE Command Sequence READ ONLY Mode tWAIT,RO tWAIT,SA t Figure 23. LF field power on reset timing LF field OFF VTHR t VDD tRESET_SETUP LF field power on reset (POR) threshold voltage Figure 24. LF field power on reset setup timing |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |