25 / 35 page ![]() Input Current (A) -25 -20 -15 -10 -5 0 5 10 15 20 25 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 -24.5 A, 0.05 V 0 A, 2.5 V 23 A, 4.8 V D001 OUT,min REF MAX V V I S OUT,max REF MAX V V I S u REF,min OUT,min IN,FS V V I S u REF,max OUT,max IN,FS V V I S 25 TMCS1100 www.ti.com SBOS820 – SEPTEMBER 2019 Product Folder Links: TMCS1100 Submit Documentation Feedback Copyright © 2019, Texas Instruments Incorporated After selecting the appropriate sensitivity variant for the application, the zero-current reference voltage defined by the VREF input pin is defined. Manipulating Equation 26 and using the linear range defined by VOUT,max, VOUT,min, and the full-scale input current, IIN,FS, calculate the maximum and minimum VREF voltages allowed to remain within the linear measurement range, shown in Equation 31 and Equation 32. (31) (32) Any value of VREF can be chosen between VREF,max and VREF,min in order to maintain the required linear sensing range. If the allowable VREF range is not wide enough or does not include a desired VREF voltage, the analysis must be repeated with a lower sensitivity variant of the TMCS1100. Equation 26 can be manipulated to solve for the maximum allowable current in either direction by using the selected VREF voltage and the maximum linear voltage ranges as in Equation 33 and Equation 34. (33) (34) Table 5 shows the respective values for the example design parameters in Table 3. In this case, a VREF of 2.5 V has been selected such that the zero current output is half of the nominal power supply. This example VREF design value provides a linear input current-sensing range of –24.5 A to +22 A, with the positive current defined as current flowing into the IN+ pin. Table 5. Example VREF Limits and Associated Current Ranges REFERENCE PARAMETER EXAMPLE VALUE MAXIMUM LINEAR CURRENT SENSING RANGE IMAX+ IMAX– VREF,min 2.05 V 26.5 A –20 A VREF,max 2.7 V 20 A –26.5 A Selected VREF 2.5 V 22 A –24.5 A The transfer function of the TMCS1100 linear sensing range for these design parameters is shown in Figure 13. Figure 13. Application Example Design Transfer Curve |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |