| поискавой системы для электроныых деталей |
|
TMCS1101 датащи(PDF) 16 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
TMCS1101 датащи(HTML) 16 Page - Texas Instruments |
|
16 / 31 page ![]() Input Current (A) -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 D003 TMCS1101AxU TMCS1101AxB Time (Ps) 0 5 10 15 20 0 5 10 15 20 25 30 6 5 4 3 2 1 0 D013 16 TMCS1101 SBOS825 – SEPTEMBER 2019 www.ti.com Product Folder Links: TMCS1101 Submit Documentation Feedback Copyright © 2019, Texas Instruments Incorporated Feature Description (continued) The output value is effectively an average over the sampling window; therefore, a large-enough current transient can drive the output voltage to the full range in the first sample response. This condition is likely to be true in the case of a short-circuit or fault event. Figure 8 shows an input-current step of 100 A, and the output response of an TMCS1101A3B. In the case of Vout1, the event occurs near the beginning of a sampling window, and so the output transitions to full scale in the first integrator output sample. In the case of Vout2, the event occurs near the end of an integration cycle, so there are two distinct output transitions. The relative timing and size of the input current transition determines whether the output transitions to full scale in a single cycle. In either case, the total response time is approximately one integration period. Figure 8. Transient Response to a Large Input Current Step 9.3.4 Internal Reference Voltage The device has an internal resistor divider from the analog supply VS that determines the zero-current output voltage, VOUT,0A. This zero-current output level along with sensitivity determine the measurable input current range of the device, and allows for unidirectional or bidirectional sensing, as described in Absolute Maximum Ratings. The TMCS1101AxB variants have a zero-current output set by Equation 12, while the TMCS1101AxU devices have a zero-current output voltage set by Equation 13. VOUT,0A = VS × 0.5 (12) VOUT,0A = VS × 0.1 (13) These respective reference voltages enable a bidirectional measurable current range for the AxB devices and a unidirectional measurement range for the AxU devices, as shown in Figure 9. Figure 9. Output Voltage Relationship to Input Current for TMCS1101A2B and TMCS1101A2U |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |