| поискавой системы для электроныых деталей |
|
CFA633-RDI-KS датащи(PDF) 57 Page - Crystalfontz America, Inc. |
|
|
|||||||||||||||||||||||||||||
CFA633-RDI-KS датащи(HTML) 57 Page - Crystalfontz America, Inc. |
|
57 / 88 page ![]() Crystalfontz America, Inc. Data Sheet Release Date 2012/02/21 www.crystalfontz.com CFA633-RDI-KS LCD Module (Hardware v2.0 / Firmware s2v1) February 2012 Page 57 29 (0x1D): Enable/Disable and Reset the Watchdog Some high-availability systems use hardware watchdog timers to ensure that a software or hardware failure does not result in an extended system outage. Once the host system has booted, a system monitor program is started. The system monitor program would enable the watchdog timer on the CFA633. If the system monitor program fails to reset the CFA633’s watchdog timer, the CFA633 will reset the host system. type: 0x1D = 2910 data_length = 1 data[0] = enable/timeout If timeout is 0, the watchdog is disabled. If timeout is 1-255, then this command must be issued again within timeout seconds to avoid a watchdog reset. To turn the watchdog off once it has been enabled, simply set timeout to 0. If the command is not re-issued within timeout seconds, then the CFA633 will reset the host (see command 28 for details). Since the watchdog is off by default when the CFA633 powers up, the CFA633 will not issue another host reset until the host has once again enabled the watchdog. The return packet will be: type: 0x40 | 0x1D = 0x5D = 9310 data_length = 0 30: Read Reporting & Status This command can be used to verify the current items configured to report to the host, as well as some other miscellaneous status information. Please note that the information returned by other modules is not identical to this. type = 0x1E = 3010 data_length = 0 The return packet will be: type = 0x40 | 0x1E = 0x5E = 9410 data_length = 15 data[0] = fan 1-4 reporting status (as set by command 16) data[1] = temperatures 1-8 reporting status (as set by command 19) data[2] = temperatures 9-15 reporting status (as set by command 19) data[3] = temperatures 16-23 reporting status (as set by command 19) data[4] = temperatures 24-32 reporting status (as set by command 19) data[5] = key presses (as set by command 23) data[6] = key releases (as set by command 23) data[7] = ATX Power Switch Functionality (as set by command 28), data[8] = current watchdog counter (as set by command 29) data[9] = fan RPM glitch delay[0] (as set by command 26) data[10] = fan RPM glitch delay[1] (as set by command 26) data[11] = fan RPM glitch delay[2] (as set by command 26) data[12] = fan RPM glitch delay[3] (as set by command 26) data[13] = contrast setting (as set by command 13) data[14] = backlight setting (as set by command 14) NOTE The GPIO pins used for ATX control must not be configured as user GPIO. They must be configured to their default drive mode in order for the ATX functions to work correctly. These settings are factory default, but may be changed by the user. Please see the note under command 28 (0x1C): Set ATX Power Switch Functionality (Pg. 54) or command 34 (0x22): Set or Set and Configure GPIO Pins (Pg. 58). |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |