16 / 25 page ![]() RFbeam Microwave GmbH RSP1 Radar Processor Datasheet Trigger Level Table (Sensitivity) Values from this tables are addressed by parameter A02 (Sensitivity) Default Values: Param A02 value 0 1 2 3 4 5 6 7 8 9 X10...X19 HEX 00DC 00BE 00A0 008C 0078 0064 003C 0028 0014 0000 Decimal 220 190 160 140 120 100 60 40 20 0 Table 11: Array Parameter X1n trigger level FFT Filter Up to 8 different, individual frequencies may be filtered by setting values according to the FFT frequency resolution (called df). Filtered frequency = Parameter X * df; See chapter 8.4 Sampling Rate and Frequency Resolution for more details. Parameter X20 X21 X22 X23 X24 X25 X26 X27 Value (HEX) 0001 000A 0 0 0 0 0 0 Filter frequency @ S03 = 2 10Hz 100Hz -- -- -- -- -- -- Table 12: Array parameter X2n filter 8.3.3 Application Parameters Application parameters are typically accessible be the end-user. Values range from 1 ..9 i(n order to become accessible by simple one digit entry. Exception: frequency filters A06 and A07. More detailed description. A01 Hold Time Sets retriggerable output hold time. Value is is a pointer to the array parameters X00 to X09. See Table 10 A02 Sensitivity Sets trigger threshold. Value is a pointer to the array parameters X10 to X19. See Table 11. Used to set an approximate maximum detection range. A03 Immunity Sets the number of consecutive internal triggers until the detection output will be set. This parameter therefore influences the output reaction time. See also chapter 5.3 Response time A04 reserved A05 direction Defines which moving direction shall be detected. This value has only effect for I/Q sensors. A06 A07 frequency limits These values build very selective frequency(=object speed) range filters. Values represent FFT bins from 1 to 127 (0x7F) in hexadecimal notation. Filters apply for both forward and backward directions. Example: Set output only for cars exceeding 53km/h. (with sampling rate set to 11.264kHz (parameter S03=09): Minimum frequency (speed) A06=35 (hex) correspondig to 53 (decimal) Maximum frequency A07=00 (no limit) © RFbeam Microwave GmbH www.rfbeam.ch December 11, 2015 16/25 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |