| поискавой системы для электроныых деталей |
|
BMA255 датащи(PDF) 39 Page - Bosch Sensortec GmbH |
|
|
|||||||||||||||||||||||||||||
BMA255 датащи(HTML) 39 Page - Bosch Sensortec GmbH |
|
39 / 119 page ![]() BMA255 Data sheet Page 39 BST-BMA255-DS004-05 | Revision 1.2 | August 2014 Bosch Sensortec © Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are subject to change without notice. 4.7.8 Flat detection The flat detection feature gives information about the orientation of the devices´ z-axis relative to the g-vector, i. e. it recognizes whether the device is in a flat position or not. The flat angle is adjustable by (0x2E) flat_theta from 0° to 44.8°. The flat angle can be set according to following formula: flat_theta 8 1 atan A hysteresis of the flat detection can be enabled by (0x2F) flat_hy bits. In this case the flat position is set if the angle drops below following threshold: 16 _ 1024 _ 1 flat_theta 8 1 atan , hy flat hy flat ll hyst The flat position is reset if the angle exceeds the following threshold: 16 _ 1024 _ 1 flat_theta 8 1 atan , hy flat hy flat ul hyst The flat interrupt is enabled (disabled) by writing ´1´ (´0´) to bit (0x16) flat_en. The flat value is stored in the (0x0C) flat bit if the interrupt is enabled. This value is ´1´ if the device is in the flat position, it is ´0´ otherwise. The flat interrupt is generated if the flat value has changed and the new value is stable for at least the time given by the (0x2F) flat_hold_time bits. A flat interrupt may be also generated if the flat interrupt is enabled. The actual status of the interrupt is stored in the (0x09) flat_int bit. The flat orientation of the sensor can always be determined from reading the (0x0C) flat bit after interrupt generation. If unlatched interrupt mode is used, the (0x09) flat_int value and hence the interrupt is automatically cleared after one sample period. If temporary or latched interrupt mode is used, the (0x09) flat_int value is kept fixed until the latch time expires or the interrupt is reset. The meaning of the (0x2F) flat_hold_time bits can be seen from Table 18. Table 18: Meaning of flat_hold_time (0x2F) flat_hold_time Time 00b 0 01b 512 ms 10b 1024 ms 11b 2048 ms |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |