11 / 35 page ![]() DocID031281 Rev 3 11/35 VL53L1X Functional description 35 2.5.2 Timing budget (TB) The VL53L1X timing budget can be set from 20 ms up to 1000 ms. • 20 ms is the minimum timing budget and can be used only in Short distance mode. • 33 ms is the minimum timing budget which can work for all distance modes. • 140 ms is the timing budget which allows the maximum distance of 4 m (in the dark on a white chart) to be reached under Long distance mode Increasing the timing budget increases the maximum distance the device can range and improves the repeatability error. However, average power consumption augments accordingly. Figure 6. Maximum distance and repeatability error vs. timing budget Test conditions: timing budget = 33 ms, 140 ms, 200 ms, grey target 54 %, ambient light = dark. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|