| поискавой системы для электроныых деталей |
|
MAS1641 датащи(PDF) 6 Page - Micro Analog systems |
|
|
|||||||||||||||||||||||||||||
MAS1641 датащи(HTML) 6 Page - Micro Analog systems |
|
6 / 14 page ![]() DA1641.004 1 February, 2019 6 (14) APPLICATION INFORMATION (continued) Figure 3. Illustration of optimal alarm threshold in increasing or decreasing capacitance sensing At alarm threshold following applies. ���������������� = ������������������������ Equation 5. ���������������� = ���������������� Equation 6. For external resistor value (RCLK, RCOM, RDEC and RINC) calculations one can derive following equations shown in the table 1. Resistor values are calculated differently whether capacitance decrease or increase is sensed. Table 1. Equations for calculating resistor values Resistor Capacitance decrease sensing (DSEL=GND) Capacitance increase sensing (DSEL=VIN) CALARM ������������������������ = ���������������� + ���������������� ���� = ���������������� + ∆���� ���� = = ���������������� ( ���������������� ���������������� + ����) ������������������������ = ���������������� + ���������������� ���� = ���������������� + ∆���� ���� = = ���������������� ∙ ( ���������������� ���������������� + ����) RCLK ���������������� = ���� ���������������� ∙ ����. ������������ ∙ ���������������� ≈ ������������ ���������������� = ���� ���������������� ∙ ����. ������������ ∙ ���������������� ≈ ������������ RCOM ���������������� = ���� ���� ∙ ���������������� ∙ ���������������� ���������������� = ���� ���� ∙ ���������������� ∙ ������������������������ RDEC ���������������� = ���������������� ∙ ( ���������������� ������������������������ − ����) 0 (shorted) RINC 0 (shorted) ���������������� = ���� ���� ∙ ���������������� ∙ ���������������� − ���������������� EXAMPLE 1: Capacitance decrease sensing fCLK = 10Hz, fREF = 100kHz, CREF = 3.2pF, CMON = 2.7pF i.e. C=CMON - CREF = 2.7pF - 3.2pF = -0.5pF CALARM = (3.2pF+2.7pF)/2=2.95pF RCLK = 1/(8192*6.1pF*10Hz)/2=2M RCOM = 1/(2*100kHz*3.2pF)=1.5625M RDEC = 1.5625M *(3.2pF/2.95pF-1)=132.4k RINC = 0 (shorted) Important note: In above RCOM and RDEC calculations there must be used non-rounded calculated resistor values. The resistor value rounding to standard series values can be done only in the next step. RCOM (E24 5% series) = 1.5625M 1.6M (E24 5% series) RDEC (E24 5% series) = 132.4k 130k (E24 5% series) Alarm threshold check: CALARM=3.2pF/(130k /1.6M+1)=2.96pF OK! (very close to target 2.95pF) |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |