| поискавой системы для электроныых деталей |
|
S29AL032D датащи(PDF) 33 Page - SPANSION |
|
|
|||||||||||||||||||||||||||||
S29AL032D датащи(HTML) 33 Page - SPANSION |
|
33 / 69 page ![]() June 13, 2005 S29AL032D_00_A3 S29AL032D 31 Ad vance Info rmat i o n Command Definitions Writing specific address and data commands or sequences into the command register initiates device operations. Table 17 on page 38 defines the valid register command sequences. Writing incorrect address and data values or writing them in the improper sequence resets the de- vice to reading array data. All addresses are latched on the falling edge of WE# or CE#, whichever happens later. All data is latched on the rising edge of WE# or CE#, whichever happens first. Refer to the appropriate tim- ing diagrams in the “AC Characteristics” section. Reading Array Data The device is automatically set to reading array data after device power-up. No commands are required to retrieve data. The device is also ready to read array data after completing an Embed- ded Program or Embedded Erase algorithm. After the device accepts an Erase Suspend command, the device enters the Erase Suspend mode. The system can read array data using the standard read timings, except that if it reads at an ad- dress within erase-suspended sectors, the device outputs status data. After completing a programming operation in the Erase Suspend mode, the system may once again read array data with the same exception. See Erase Suspend/Erase Resume Commands on page 35 for more in- formation on this mode. The system must issue the reset command to re-enable the device for reading array data if DQ5 goes high, or while in the autoselect mode. See the Reset Command on page 32 section, next. See also Requirements for Reading Array Data on page 11 for more information. The Read Operations on page 50 provides the read parameters, and Figure 14, on page 50 shows the timing diagram. 48h 90h 0001h Sector Temporary Unprotect 00 = Not Supported, 01 = Supported 49h 92h 0004h Sector Protect/Unprotect scheme 01 = 29F040 mode, 02 = 29F016 mode, 03 = 29F400 mode, 04 = 29LV800A mode 4Ah 94h 0000h Simultaneous Operation 00 = Not Supported, 01 = Supported 4Bh 96h 0000h Burst Mode Type 00 = Not Supported, 01 = Supported 4Ch 98h 0000h Page Mode Type 00 = Not Supported, 01 = 4 Word Page, 02 = 8 Word Page 4Dh 9Ah 00B5h ACC (Acceleration) Supply Minimum 00h = Not Supported, D7-D4: Volt, D3-D0: 100 mV 4Eh 9Ch 00C5h ACC (Acceleration) Supply Maximum 00h = Not Supported, D7-D4: Volt, D3-D0: 100 mV 4Fh 9Eh 000xh Top/Bottom Boot Sector Flag (0 = Model 00, 2 = Model 03, 3 = Model 04) Table 15. Primary Vendor-Specific Extended Query (Sheet 2 of 2) Addresses Addresses (Models 03, 04 Byte Mode Only) Data Description |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |