8 / 28 page ![]() ZL2103 FN6966 Rev 5.00 Page 8 of 28 May 3, 2011 VSEN Undervoltage Threshold Factory default - 85 - % VOUT Configurable via I2C/SMBus 0 - 110 % VOUT VSEN Overvoltage Threshold Factory default - 115 - % VOUT Configurable via I2C/SMBus 0 - 115 % VOUT VSEN Undervoltage Hysteresis - 5 - % VOUT VSEN Undervoltage/Overvoltage Fault Response Time Factory default - 16 - µs Configurable via I2C/SMBus 5 - 60 µs Peak Current Limit Threshold Factory default - - 4.5 A Configurable via I2C/SMBus 0.2 - 4.5 A Current Limit Set-point Accuracy - ±10 - % FS (Note 12) Current Limit Protection Delay Factory default - 5 - tSW (Note 19) Configurable via I2C/SMBus 1 - 32 tSW (Note 19) Thermal Protection Threshold (Junction Temperature) Factory default - 125 - °C Configurable via I2C/SMBus -40 - 125 °C Thermal Protection Hysteresis - 15 - °C NOTES: 10. Refer to Safe Operating Area in Figure 8 and thermal design guidelines in AN2010. 11. Does not include margin limits. 12. Percentage of Full Scale (FS) with temperature compensation applied. 13. The device requires a delay period following an enable signal and prior to ramping its output. Precise timing mode limits this delay period to approx 2ms, where in normal mode it may vary up to 4ms. 14. Precise ramp timing mode is only valid when using EN pin to enable the device rather than PMBus enable. Precise ramp timing mode is automatically disabled for a self-enabled device (EN pin tied high). 15. The devices may require up to a 4ms delay following the assertion of the enable signal (normal mode) or following the de-assertion of the enable signal. Precise mode requires Re-Enable delay = TOFF+TFALL+10µs. 16. Switch node current should not exceed IRMS of 3A. 17. Factory default is the initial value in firmware. The value can be changed via PMBus commands. 18. Maximum duty cycle is limited by the equation MAX_DUTY(%) = [1 - (150×10-9 × fSW)] × 100 and not to exceed 95%. 19. tSW = 1/fSW, where fSW is the switching frequency. 20. Compliance to datasheet limits is assured by one or more methods: production test, characterization and/or design. Electrical Specifications V DDP = VDDS = 12V, TA = -40°C to +85°C unless otherwise noted. (Note 10) Typical values are at TA = +25°C. Boldface limits apply over the operating temperature range, -40°C to +85°C. (Continued) PARAMETER CONDITIONS MIN (Note 20) TYP MAX (Note 20) UNIT |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |