| поискавой системы для электроныых деталей |
|
S82K датащи(PDF) 12 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
S82K датащи(HTML) 12 Page - List of Unclassifed Manufacturers |
|
12 / 20 page ![]() L-16 Switch mode Power Supply S82K Operation I Undervoltage Alarm Indicator and Output Function (All Models Except for S82K-24024/P24024) If the output voltage at the output terminal drops to 75% to 90% of the rated voltage, the red indicator of the S82K (DC LOW indicator) will be lit. In the case of the S82K- @09024/@10024/24024T, a voltage drop alarm will be output via the relay available in the models (DC LOW output). Note: This function detects the voltage at the output terminal of the Power Supply. To check the precise output voltage, measure the voltage at the terminal of the load. Note: 1. The more the voltage at the output terminal drops, the darker both the green and red indicators will be. 2. The relay contacts have a capacity of 0.1 A at 24 VDC. 3. The red indicator will actually first light at a voltage between 75% and 90% of the rated voltage. Engineering Data I Reference Value I Derating Curve Indicator Voltage Operation of @09024/@10024/ 24024T’s output (DC LOW output) (see note 2) If the voltage at the output terminal is more than 82% of the rated voltage and operation is normal, the green in- dicator will be lit and the red indicator will not be lit. If the voltage at the output terminal drops to below 82% of the rated voltage, the red indicator will be lit. (See note 3.) If the voltage at the output terminal approaches 0 V, both the green and red indicators will not be lit. Green: DC ON Red: DC LOW Green: DC ON Red: DC LOW (see note 1) Green: DC ON Red: DC LOW Item Value Definition Reliability (MTBF) 135,000 hrs min. MTBF stands for Mean Time Between Failures, which is calculated according to the prob- ability of accidental device failures, and indicates reliability of devices. Therefore, it does not necessarily represent a life of the product. Life expectancy 8 yrs. min. The life expectancy indicates average operating hours under the ambient temperature of 40 °C and a load rate of 50%. Normally this is determined by the life expectancy of the built- in aluminum electrolytic capacitor. 65 65 90 Ambient temperature ( °C) 3-/7.5-/15-/30-/50-/100-W Models Ambient temperature ( °C) Ambient temperature ( °C) Installation A Installation A Installation B 100-W Models with PFC Installation B Parallel-Unit Operation 100-W Models without PFC Installation A Installation B Single-Unit Operation Parallel-Unit Operation S82K-P10024: 85-VAC input S82K-03005 Installation A Note: When using the 7.5-W single-output models within the input voltage range between 90 and 110 VDC, the load rate will become 90% or less. S82K-P10024: 85-VAC input |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |