| поискавой системы для электроныых деталей |
|
S82K датащи(PDF) 19 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
S82K датащи(HTML) 19 Page - List of Unclassifed Manufacturers |
|
19 / 20 page ![]() Switch mode Power Supply S82K L-23 Wiring Carefully wire the input/output terminals while paying attention to their polarities so as to prevent incorrect wiring. Battery Charging/Backup With S82K- @09024/-@10024/-24024T models, a reduction in lifetime due to over discharge of the battery can be prevented using the DC LOW output. (Discharge can be interrupted at 0.75 to 0.9 × 24 V.) Note: 1. For details of charging voltages and charging currents, refer to the specifications for the battery. 2. In order to prevent overvoltage to the battery, install an ov- ervoltage protection circuit (90/100-W models). 3. To protect the battery in the event of incorrect operation, such as load short-circuiting, be sure to install a fuse or cir- cuit breaker. 4. To limit the level of charging current to the battery, install an overcurrent limit circuit. With other models, when connecting a battery to the load, install an overcurrent limit circuit and overvoltage protection circuit. Series Operation S82K 90-W/100-W/240-W model can be operated in series. It must be noted that the + output of the 7.5-W dual output model cannot be connected in series to its – output. Parallel Operation S82K 100-W/240-W models can be operated in parallel. Perform parallel operation with power supplies satisfying the same specifications. Note: When operating the S82K-P10024 or S82K- @24024@ in paral- lel operation, set the switch to “PARALLEL.” Refer to the derat- ing curve for the rated current under this operation. Parallel Operation Precautions • The length and thickness of each wire connected to the load must be the same so that there is no difference in voltage drop value between the load and the output terminals of each Power Supply. • Adjust the output voltage of each Power Supply so that there will be no difference in output voltage between each Power Supply. • If the S82K-P10024 or S82K- @24024@ models are used in single operation under the parallel operation setting, the overcurrent pro- tection will be actuated at an output of 90% to 95% (in current), and will not allow a 100% output. • If the S82K-P10024 or S82K- @24024@ models are used in parallel operation under the single operation setting, one of them will oper- ate at 110% output, causing severe heat derating and shortening the service life. 14 15 16 +V −V 9 10 11 12 13 Example: Lead Storage Battery Backup Circuit Fuse/Circuit breaker DC Low +V −V +V −V +V −V +V −V 90-, 100-, and 240-W Models 3-, 7.5-, 15-, 30-, 50-W Models INPUT INPUT INPUT INPUT +V −V +V −V INPUT INPUT Load 100- and 240-W Models +V −V +V −V INPUT INPUT Load 3-, 7.5-, 15-, 30-, 50- and 90-W Models |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |