| поискавой системы для электроныых деталей |
|
AS3956 датащи(PDF) 94 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS3956 датащи(HTML) 94 Page - ams AG |
|
94 / 109 page ![]() Page 94 ams Datasheet Document Feedback [v1-10] 2018-Apr-27 AS3956 − Application Information Following is an example of an NDEF message with one Well Known URL record, which carries the http://www.ams.com URL: • In the NDEF message format, the URL above will be represented by the bytes: [D1 01 08 55 01 61 6D 73 2E 63 6F 6D]h • The NDEF Message TLV will have the content: [03 0C D1 01 08 55 01 61 6D 73 2E 63 6F 6D]h; first byte is 03h – T field value, indicating this is an NDEF Message TLV, second byte is 0Ch saying the V field is 12 bytes long, the following 12 bytes are the V field holding the NDEF message. The NDEF message TLV given above will fully occupy the first 3 blocks of the data area and the first two bytes of the 4th block of the data area (each memory block is 4 bytes long). Reading/Writing with an NFC Device NFC devices use the T2T WRITE command to write data into a T2T platform. The T2T WRITE command consists of 6 bytes, 1st byte is the command code – A2h, 2nd byte is the block number where data is to be written and the remaining 4 bytes are the data content. When the execution of the command is successful, the tag will return an ACK response – A0h. In case of failure, a NACK code will be returned (see Error Handling section of this datasheet for NACK codes). If a write EEPROM command is the very last command to be sent from an NFC device then it is good practice to read back the data sent in the last write command. This is because EEPROM writing takes longer to execute. A successful read back will confirm the RF field and hence power was maintained during the EEPROM write and that the write was successful. The T2T READ command consists of 2 bytes, first byte is the command code and is equal to 30h, second byte is the first block number from which data will be returned. The response, when successful, will return 4 blocks of data, each block is 4 bytes long, so 16 bytes of data. In case of error, one byte NACK response will be returned (see Error Handlingsection of AS3956 datasheet for NACK codes). AS3956 has to be configured in Extended or Normal mode in order for an NFC device to write/read NDEF data from the EEPROM of the tag. An NFC device has to send 4 write commands to the tag to write the NDEF Message TLV bytes [03 0C D1 01 08 55 01 61 6D 73 2E 63 6F 6D]hex defined in the section above into blocks 04h-07h: 1. [A2 04 03 0C D1 01]hex 2. [A2 05 08 55 01 61]hex 3. [A2 06 6D 73 2E 63]hex 4. [A2 07 6F 6D 00 00]hex |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |