| поискавой системы для электроныых деталей |
|
MP023GS датащи(PDF) 15 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP023GS датащи(HTML) 15 Page - Monolithic Power Systems |
|
15 / 23 page ![]() MP023 – PRIMARY-SIDE CC/CV CONTROLLER MP023 Rev. 1.1 www.MonolithicPower.com 15 7/18/2016 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2016 MPS. All Rights Reserved. Figure 9: The External Configuration of CP Table 1 shows all available values for DS-Max. The entire customization process is completed before start-up and latched in a register, so it does not have any influence on normal operation. Table 1: DS-Max vs. CP Configuration RCP/CCP DS-Max 0 Ω/NC * 0.4 10 kΩ/NC 0.3 20 kΩ/NC 0.35 40 kΩ/NC 0.5 NC/1μF 0.4 Notes: * NC means no connection. Ipk is also fixed in CC operation. The relationship between the output constant current and secondary peak current (Ipks) can be calculated with Equation (7): ons out pks pks S Max ons offs t 11 II I D 2t t 2 (7) When the secondary diode is turned on, the peak current on the secondary side is calculated with Equation (8): p pks PK S N II N (8) The output current is then calculated with Equation (9): p out PK S Max S N 1 II D 2N (9) To implement the OLP function in CC mode, the sampling on the FB voltage continues running with the sampling time fixed at tFBS-Max. Leading Edge Blanking Turning the power switch on induces a spike on the sense resistor. The MP023 employs a leading edge blanking period (tLEB) to avoid falsely terminating the switching pulse. During this blanking period, the current sense comparator is disabled, and the part cannot be turned off. DCM Detection The MP023 is designed to operate in discontinuous conduction mode (DCM) in both CV and CC modes. To avoid operating in continuous conduction mode (CCM), the MP023 implements a zero current detection (ZCD) function internally with a threshold of VDCM. The IC does not start the next cycle until ZCD is detected. During normal operation, the blanking time for ZCD is synchronized with the FB sampling time (i.e., ZCD always starts after the sampling phase is done). There is also a soft-start function on the ZCD blanking time to prevent ZCD from being triggered falsely when the output capacitor is not charged up. During the start-up period, the blanking time for ZCD shrinks gradually from tB_STP (10μs) to the FB sampling time in 3 cycles. OVP, OCkP, and OLP The MP023 includes over-voltage protection (OVP), open-circuit protection (OCkP), and overload protection (OLP). If the voltage on FB exceeds VFBovp, OVP is triggered. If VFBopen cannot be monitored for each cycle, OCkP is triggered. If the sampled FB voltage is lower than VFBolp for 128 consecutive cycles, OLP is triggered. When any of these protections are triggered, the MP023 shuts off immediately, enters hiccup mode, and resumes normal operation (tons) when the fault has been removed. OLP is not enabled until the soft-start period of the ZCD blanking time is finished. Over-Temperature Protection (OTP) When the temperature of the IC exceeds 150°C, the over-temperature protection (OTP) is activated, and the IC enters auto-recovery mode. When the temperature falls below 120°C, the IC resumes operation. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |