| поискавой системы для электроныых деталей |
|
MP5403 датащи(PDF) 14 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP5403 датащи(HTML) 14 Page - Monolithic Power Systems |
|
14 / 22 page ![]() MP5403 – CONFIGURABLE 2.7V-6V MINI PMIC WITH DUAL 2.5A/3.5A BUCK, ONE LOAD SWITCH, AND INPUT POWER SUPERVISORY MP5403 Rev. 1.0 www.MonolithicPower.com 14 9/20/2016 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2016 MPS. All Rights Reserved. PIN FUNCTIONS Pin # Name Description 1 CDELAY Programmable PFL low-to-high delay time. When CDELAY is floated, the delay time is minimized. 2 PFL_ADJ Power failure threshold adjust. A resistor divider connected to the voltage rails is used to program the power failure threshold. The resistor divider needs to be monitored. 3 VIN1 Input supply voltage to the 3.5A switching regulators and internal logic module. Place a small decoupling capacitor as close to VIN1 and GND as possible. 4 AGND Analog ground. 5 GND Ground. 6 VIN2 Input supply voltage to the 2.5A switching regulators. Place a small decoupling capacitor as close to VIN2 and GND as possible. 7 FB1 Feedback voltage sensing for the 3.5A regulator. Connect the output voltage of the 3.5A regulator through a resistor divider to FB1 to achieve output voltage regulation. Pull FB1 to ground to operate the 3.5A regulator in 100% duty cycle on mode. 8 FB2 Feedback voltage sensing for the 2.5A regulator. Connect the output voltage of the 2.5A regulator through a resistor divider to FB2 to achieve output voltage regulation. Pull FB2 to ground to operate the 2.5A regulator in 100% duty cycle on mode. 9 EN1 Enable on/off control for the 3.5A regulator. There is a 2MΩ resistor from EN1 to GND internally. Float or ground EN1 to turn off the 3.5A regulator. 10 EN2 Enable on/off control for the 2.5A regulator. There is a 2MΩ resistor from EN2 to GND internally. Float or ground EN2 to turn off the 2.5A regulator. 11 EN3 Enable on/off control for the load switch. There is a 2M Ω resistor from EN3 to GND internally. Float or ground EN3 to turn off the load switch. 12 SW2 Switch output for the 2.5A regulator. A thick and wide power routing trace is recommended for SW2 to conduct current. 13 VSUS Sustain voltage. Place a small decoupling capacitor as close to VSUS and GND as possible. 14 SW1 Switch output for the 3.5A regulator. A thick and wide power routing trace is recommended for SW1 to conduct current. 15 PG1 Power good for the 3.5A regulator. PG1 is an open-drain output. When the output voltage is between -10% to +30% of the regulation, PG1 is pulled high externally. When there is no supply, PG1 is pulled low internally. 16 PG2 Power good for the 2.5A regulator. PG2 is an open-drain output. When the output voltage is between -10% to +30% of the regulation, PG2 is pulled high externally. When there is no supply, PG2 is pulled low internally. 17 PG3 Power good for the load switch. PG3 is an open-drain output. When the output voltage is below 200mV compared with the input voltage, PG3 is pulled high externally. 18 VIN3 Input supply voltage for the load switch. 19 OUT3 Output voltage for the load switch. 20 PFL Power failure indicator. PFL is an open-drain output. When the PFL_ADJ voltage is less than 0.6V, PFL is pulled low immediately. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |