| поискавой системы для электроныых деталей |
|
SIT2018B датащи(PDF) 7 Page - SiTime Corp. |
|
|
|||||||||||||||||||||||||||||
SIT2018B датащи(HTML) 7 Page - SiTime Corp. |
|
7 / 17 page ![]() The Smart Timing Choice The Smart Timing Choice SiT2018B High Temp, Single-Chip, One-Output Clock Generator Rev. 1.0 Page 7 of 12 www.sitime.com Programmable Drive Strength The SiT2018 includes a programmable drive strength feature to provide a simple, flexible tool to optimize the clock rise/fall time for specific applications. Benefits from the programmable drive strength feature are: • Improves system radiated electromagnetic interference (EMI) by slowing down the clock rise/fall time • Improves the downstream clock receiver’s (RX) jitter by de- creasing (speeding up) the clock rise/fall time. • Ability to drive large capacitive loads while maintaining full swing with sharp edge rates. For more detailed information about rise/fall time control and drive strength selection, see the SiTime Application Notes section: http://www.sitime.com/support/application-notes. EMI Reduction by Slowing Rise/Fall Time Figure 16 shows the harmonic power reduction as the rise/fall times are increased (slowed down). The rise/fall times are expressed as a ratio of the clock period. For the ratio of 0.05, the signal is very close to a square wave. For the ratio of 0.45, the rise/fall times are very close to near-triangular waveform. These results, for example, show that the 11th clock harmonic can be reduced by 35 dB if the rise/fall edge is increased from 5% of the period to 45% of the period. Figure 16. Harmonic EMI reduction as a Function of Slower Rise/Fall Time Jitter Reduction with Faster Rise/Fall Time Power supply noise can be a source of jitter for the downstream chipset. One way to reduce this jitter is to speed up the rise/fall time of the input clock. Some chipsets may also require faster rise/fall time in order to reduce their sensitivity to this type of jitter. Refer to the Rise/Fall Time Tables (Table 7 to Table 11) to determine the proper drive strength. High Output Load Capability The rise/fall time of the input clock varies as a function of the actual capacitive load the clock drives. At any given drive strength, the rise/fall time becomes slower as the output load increases. As an example, for a 3.3V SiT2018 device with default drive strength setting, the typical rise/fall time is 1ns for 15 pF output load. The typical rise/fall time slows down to 2.6 ns when the output load increases to 45 pF. One can choose to speed up the rise/fall time to 1.83 ns by then increasing the drive strength setting on the SiT2018. The SiT2018 can support up to 60 pF in maximum capacitive loads with drive strength settings. Refer to the Rise/Tall Time Tables (Table 7 to 11) to determine the proper drive strength for the desired combination of output load vs. rise/fall time SiT2018 Drive Strength Selection Tables 7 through 11 define the rise/fall time for a given capac- itive load and supply voltage. 1. Select the table that matches the SiT2018 nominal supply voltage (1.8V, 2.5V, 2.8V, 3.0V, 3.3V). 2. Select the capacitive load column that matches the appli- cation requirement (5 pF to 60 pF) 3. Under the capacitive load column, select the desired rise/fall times. 4. The left-most column represents the part number code for the corresponding drive strength. 5. Add the drive strength code to the part number for ordering purposes. Calculating Maximum Frequency Based on the rise and fall time data given in Tables 7 through 11, the maximum frequency the oscillator can operate with guaranteed full swing of the output voltage over temperature can be calculated as the following: where Trf_20/80 is the typical value for 20%-80% rise/fall time. Example 1 Calculate fMAX for the following condition: • Vdd = 1.8V (Table 7) • Capacitive Load: 30 pF • Desired Tr/f time = 3 ns (rise/fall time part number code = E) Part number for the above example: SiT2018BIES2-18E-66.666660 Drive strength code is inserted here. Default setting is “-” 1 3579 11 -80 -70 -60 -50 -40 -30 -20 -10 0 10 Harm onic number trise=0.05 trise=0.1 trise=0.15 trise=0.2 trise=0.25 trise=0.3 trise=0.35 trise=0.4 trise=0.45 = 1 5 x T rf_ 2 0 /8 0 M a x F re que ncy |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |