| поискавой системы для электроныых деталей |
|
MP4575 датащи(PDF) 12 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP4575 датащи(HTML) 12 Page - Monolithic Power Systems |
|
12 / 22 page ![]() MP4575 – 5A, 55V, SYNCHRONOUS, STEP-DOWN CONVERTER MP4575 Rev. 1.0 www.MonolithicPower.com 12 8/16/2016 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2016 MPS. All Rights Reserved. PIN FUNCTIONS Pin # Name Description 1 COMP Compensation network setting. Connect an external resistor in series with a capacitor between COMP and GND. 2 FB Feedback. FB is the input to the PWM comparator. Place an external resistor divider between the output and GND. 3 FREQ Switching frequency setting. Connect a resistor from FREQ to GND to set the switching frequency. If an external synchronous clock is applied to FREQ, the converter follows this clock ’s frequency. 4 EN Enable input. Pull EN below the specified threshold to shut down the MP4575. There is no internal pull-up or pull-down circuit. Do not float EN. 5 BST Bootstrap. BST is the positive power supply for the internal floating high-side MOSFET driver. Connect a capacitor between BST and SW. 6, 7, 8 VIN Input supply. VIN supplies power to all of the internal control circuitries and VDD regulator. A decoupling capacitor to ground must be placed close to VIN to minimize switching spikes. 9, 12 NC No connection. Leave NC floating. 10, 11 SW Switch node. SW is the output node from the internal high-side MOSFET source. 13, 14, 15, Exposed Pad GND Power ground for the internal power MOSFETs. 16 VDD Power for the internal MOSFET driver and BST charging circuit. 17 BIAS Optional supply for the internal circuit. For better thermal performance, connect BIAS to an external 5V source. VDD and the internal circuit are powered by BIAS. Since there is a diode between BIAS and the internal circuit, leave BIAS floating or connect it to GND if BIAS is not used. 18 PG Power good indicator. Connect a resistor to a pull-up power source if used. 19 SS Optional external soft-start time setting. Connect an external capacitor between SS and GND to set the soft-start time externally. Float SS to activate the internal 0.5ms soft-start setting. 20 AGND Ground for internal logic and signal circuit. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |