| поискавой системы для электроныых деталей |
|
S71PL254 датащи(PDF) 49 Page - SPANSION |
|
|
|||||||||||||||||||||||||||||
S71PL254 датащи(HTML) 49 Page - SPANSION |
|
49 / 196 page ![]() August 12, 2004 S29PL127J_064J_032J_MCP_00_A3 S29PL127J/S29PL064J/S29PL032J for MCP 49 Advance I n f o rmatio n Autoselect Mode The autoselect mode provides manufacturer and device identification, and sector protection verification, through identifier codes output on DQ7–DQ0. This mode is primarily intended for programming equipment to automatically match a device to be programmed with its corresponding programming algorithm. However, the autoselect codes can also be accessed in-system through the command register. When using programming equipment, the autoselect mode requires VID on ad- dress pin A9. Address pins must be as shown in Table 8 and Table 11. In addition, when verifying sector protection, the sector address must appear on the appro- priate highest order address bits (see Table 3). Table 8 and Table 11 show the remaining address bits that are don’t care. When all necessary bits have been set as required, the programming equipment may then read the corresponding iden- tifier code on DQ7–DQ0. However, the autoselect codes can also be accessed in- system through the command register, for instances when the device is erased or programmed in a system without access to high voltage on the A9 pin. The command sequence is illustrated in Table 17. Note that if a Bank Address (BA) (on address bits PL127J: A22–A20, PL064J: A21–A19, PL032J: A20–A18) is as- serted during the third write cycle of the autoselect command, the host system can read autoselect data that bank and then immediately read array data from the other bank, without exiting the autoselect mode. To access the autoselect codes in-system, the host system can issue the autose- lect command via the command register, as shown in Table 17. This method does not require VID. Refer to the Autoselect Command Sequence for more information. Legend: L = Logic Low = VIL, H = Logic High = VIH, BA = Bank Address, SA = Sector Address, X = Don’t care. Note: The autoselect codes may also be accessed in-system via command sequences Table 8. Autoselect Codes (High Voltage Method) Description CE# OE# WE# Amax to A12 A1 0 A9 A8 A7 A6 A5 to A4 A3 A2 A1 A0 DQ15 to DQ0 Manufacturer ID: Spansion products L L H BA X VID X L L X L L L L 0001h Read Cycle 1 L L H BA X VID X L L L L L L H 227Eh Read Cycle 2 L H H H L 2220h (PL127J) 2202h (PL064J) 220Ah (PL032J) Read Cycle 3 L H H H H 2200h (PL127J) 2201h (PL064J) 2201h (PL032J) Sector Protection Verification L L H SA X VID X L L L L L H L 0001h (protected), 0000h (unprotected) Secured Silicon Indicator Bit (DQ7, DQ6) L L H BA X VID X X L X L L H H 00C4h (factory and customer locked), 0084h (factory locked), 0004h (not locked) |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |