| поискавой системы для электроныых деталей |
|
AD7294 датащи(PDF) 30 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD7294 датащи(HTML) 30 Page - Analog Devices |
|
30 / 48 page ![]() Data Sheet AD7294 Rev. I | Page 29 of 47 ADC Channel Allocation The three channel address bits indicate which channel the result in the result register represents. Table 13 details the channel ID bits (S.E. indicates single-ended and DIFF indicates differential). Table 13. ADC Channel Allocation Function Channel ID CHID2 CHID1 CHID0 VIN0 (S.E.) or VIN0 − VIN1 (DIFF) 0 0 0 VIN1 (S.E.) or VIN1 − VIN0 (DIFF) 0 0 1 VIN2 (S.E.) or VIN2 − VIN3 (DIFF) 0 1 0 VIN3 (S.E.) or VIN3 − VIN2 (DIFF) 0 1 1 ISENSE1 1 0 0 ISENSE2 1 0 1 TSENSE1 1 1 0 TSENSE2 1 1 1 TSENSE1, TSENSE2 RESULT REGISTERS (0X02 AND 0X03) Register TSENSE1 and Register TSENSE2 are 16-bit read only registers. The MSB, D15 is the alert_flag bit whereas Bit D14 to Bit D12 contain the three ADC channel allocation bits. D11 is reserved for flagging diode open circuits. The temperature reading from the ADC is stored in an 11-bit twos complement format, D10 to D0 (see Table 14 and Table 15). Conversions take place approx- imately every 5 ms. Table 14. TSENSE Register (First Read) MSB LSB D15 D14 D13 D12 D11 D10 D9 D8 Alert_Flag CHID2 CHID1 CHID0 B11 B10 B9 B8 Table 15. Register (Second Read) MSB LSB D7 D6 D5 D4 D3 D2 D1 D0 B7 B6 B5 B4 B3 B2 B1 B0 TSENSEINT RESULT REGISTER (0X04) The TSENSEINT register is a 16-bit read-only register used to store the ADC data generated from the internal temperature sensor. Similar to the TSENSE1 and TSENSE2 result registers, this register stores the temperature readings from the ADC in an 11- bit twos complement format, D10 to D0, and uses the MSB as a general alert flag. Bits[D14:D11] are not used and are set to zero. Conversions take place approximately every 5 ms. The temperature data format in Table 16 also applies to the internal temperature sensor data. Temperature Value Format The temperature reading from the ADC is stored in an 11-bit twos complement format, D10 to D0, to accommodate both positive and negative temperature measurements. The temper- ature data format is provided in Table 16. Table 16. TSENSE Data Format Input D10 (MSB) D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 (LSB) Value (°C) −256 +128 +64 +32 +16 +8 +4 +2 +1 +0.5 +0.25 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |