| поискавой системы для электроныых деталей |
|
LP87332D датащи(PDF) 16 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
LP87332D датащи(HTML) 16 Page - Texas Instruments |
|
16 / 74 page ![]() FB + - + - POWER GOOD LOOP COMP RAMP GENERATOR HS FET CURRENT SENSE LS FET CURRENT SENSE GATE CONTROL IADC VDAC ERROR AMP GND NEG CURRENT LIMIT ZERO CROSS DETECT SW POS CURRENT LIMIT VIN VOUT CONTROL BLOCK PROGRAMMABLE PARAMETERS SLAVE INTERFACE VOLTAGE SETTING SLEW RATE CONTROL MASTER INTERFACE Copyright © 2016, Texas Instruments Incorporated 16 LP87332D SNVSAU6 – NOVEMBER 2017 www.ti.com Product Folder Links: LP87332D Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Feature Description (continued) • Average output current sensing (for PFM entry and load current measurement) The following parameters can be programmed via registers, the default values are set by OTP bits: • Output voltage • Forced PWM operation • Switch current limit • Output voltage slew rate • Enable and disable delays There are two modes of operation for the buck converter, depending on the output current required: pulse-width modulation (PWM) and pulse-frequency modulation (PFM). The converter operates in PWM mode at high load currents of approximately 600 mA or higher. Lighter output current loads cause the converter to automatically switch into PFM mode for reduced current consumption when forced PWM mode is disabled. The forced PWM mode can be selected to maintain fixed switching frequency at all load current levels. A block diagram of a single core is shown in Figure 6. Figure 6. Detailed Block Diagram Showing One Core 7.3.1.2 Transition Between PWM and PFM Modes PWM mode operation optimizes efficiency at mid to full load at the expense of light-load efficiency. The LP87332D converter operates in PWM mode at load current of about 600 mA or higher. At lighter load current levels the device automatically switches into PFM mode for reduced current consumption when forced PWM mode is disabled (AUTO mode operation). By combining the PFM and the PWM modes a high efficiency is achieved over a wide output-load current range. 7.3.1.3 Buck Converter Load Current Measurement Buck load current can be monitored via I2C registers. The monitored buck converter is selected with the LOAD_CURRENT_BUCK_SELECT bit in SEL_I_LOAD register. A write to this selection register starts a current measurement sequence. The regulator is automatically forced to PWM mode for the measurement period. The measurement sequence is 50 µs long, maximum. LP87332D can be configured to give out an interrupt (I_MEAS_INT bit in INT_TOP_1 register) after the load current measurement sequence is finished. Load current measurement interrupt can be masked with I_MEAS_MASK bit (TOP_MASK_1 register). The measurement result can be read from registers I_LOAD_1 and I_LOAD_2. Register I_LOAD_1 bits BUCK_LOAD_CURRENT[7:0] give out the LSB bits and register I_LOAD_2 bit BUCK_LOAD_CURRENT[8] the MSB bit. The measurement result BUCK_LOAD_CURRENT[8:0] LSB is 20 mA, and maximum code value of the measurement corresponds to 10.22 A. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |