| поискавой системы для электроныых деталей |
|
STV3550 датащи(PDF) 114 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STV3550 датащи(HTML) 114 Page - STMicroelectronics |
|
114 / 144 page ![]() 114/144 STV3550 The arbitration scheme does not affect the data transmitted by the winning master. Consequently, arbitration proceeds concurrently with data transmission and valid data will have been received by the selected slave during the arbitration process. It is possible that the winning master is actually addressing the losing master and hence this device must respond as if it were a slave device. Arbitration is implemented in hardware by comparing the transmitted and received data bits every cycle. Loss of arbitration is indicated by the setting of the SSCARBL, arbitration lost error flag in the status register. An interrupt will also occur if the SSCARBLEN bit is set in the interrupt enables register. Loss of arbitration also causes a clock stretch to be inserted. The interrupt and the clock stretch will occur immediately after the 8 bits plus acknowledge. The arbitration lost status and interrupt will be cleared by a read of the status register. The clock stretch is cleared when the software writes to the transmit buffer. 7.7.25 I²C Timing Specification The I²C specification defines a number of timing constraints which must be met on the output clock and data pins. The key values which must be met are described in Table 24. Table 24: Key I²C Timing Requirements Parameter MIN MAX SCL Clock Frequency 100KHZ or 400KHz1 1. In FAST Mode Hold Time of SCL after SDA START or REPSTART Condition. After this time the first clock low pulse is created 1.0us or 0.6us 1 LOW Period of the SCL clock 4.7us or 1.3us 2 HIGH period of the SCL clock 4.0us or 0.6us 1 SDA Set-up time relative to SCL for a repeated START condition 4.6us or 0.6us 1 SDA Data Hold Time relative to SCL 300ns2 2. Actual requirement is 0ns but hold time must be at least 300ns on SDA line to comply with uncertain period of max fall time of 300ns on the SCL line. SDA Data Setup Time relative to SCL 250ns or 100ns3 Rise time of SDA and SCL lines 20+0.1Cb 4 100ns or 300ns 1 Fall time of SDA and SCL lines 20+0.1Cb 3 300ns SDA Setup time relative to SCL for a STOP condition 4.0us or 0.6us 1 Capacitive load of each bus line (Cb) 400pF |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |