4 / 18 page ![]() SPEC-1587 (REV. 5) 4/18 29-09-2017 SA4106A PIN DESCRIPTION Designation Pin No. Description AGND 20 Analog Ground. This is the reference pin for the current and voltage signal sensing networks. The supply voltage to this pin should be mid-way between VDD and VSS. VDD 8 Positive Supply Voltage. The voltage to this pin should be +2.5V ± 10% with respect to AGND. VSS 14 Negative Supply Voltage. The voltage to this pin should be -2.5V ± 10% with respect to AGND. IVP 19 Analog Input for Voltage. The maximum current into the voltage sense input IVP should be set at 16µARMS. The voltage sense input saturates at an input current of ±25µA peak. IIP, IIN 2, 1 Analog Inputs for Current. The maximum current into the current sense inputs IIP/IIN should be set at 16µARMS. The current sense inputs saturate at an input current of ±25µA peak. VREF 3 This pin provides the connection for the reference current setting resistor. A 47k resistor connected to VSS sets the optimum operating conditions. R0, R1, R2, R3 6, 5, 4, 11 Rated Condition Select inputs. These input pins are used for selecting between the different rated condition configurations. Refer to the Rated Condition Select section. FMS 7 Fast Mode Select input. This three state input is used to select between STANDARD and FAST mode and provides an extended selection of meter constants. Refer to the Rated Condition Select and Fast Mode Select sections. DIRI 18 Direction Select input. This input is used to enable either bidirectional or unidirectional energy measurement. ACSEL 9 Anti-Creep Threshold Select input. This three state input is used to select the anti-creep threshold. It is also used to deactivate the anti-creep feature. Refer to the Anti-Creep Threshold Select section. ACST 16 Anti-Creep State output. This output pin indicates the state of the anti-creep circuit. Refer to the Anti-Creep State Output section. DIRO 17 Direction Indicator output. This output indicates the direction of energy flow. LED 13 Calibration LED output. Refer to the Rated Condition Select section for the pulse rate output options. MON, MOP 15, 12 Motor pulse outputs. These outputs can drive an electro-mechanical counter directly. Refer to the Rated Condition Select section for the pulse rate output options. NC 10 No connection, leave unconnected. Figure 3: Pin connections ORDERING INFORMATION Part Number Package SA4106ASAR SOIC20 (RoHS compliant) 1 2 3 4 5 6 7 8 20 19 18 17 IIN IIP VREF R2 R1 R0 FMS VDD IVP DIRI DIRO 9 10 16 15 ACSEL NC ACST MON AGND 14 13 VSS LED 12 11 MOP R3 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |