  SA2102DSA Datasheet HTML 1Page - Sames SA2102DSA Datasheet HTML 2Page - Sames SA2102DSA Datasheet HTML 3Page - Sames SA2102DSA Datasheet HTML 4Page - Sames SA2102DSA Datasheet HTML 5Page - Sames SA2102DSA Datasheet HTML 6Page - Sames SA2102DSA Datasheet HTML 7Page - Sames SA2102DSA Datasheet HTML 8Page - Sames SA2102DSA Datasheet HTML 9Page - Sames Next Button
Zoom Inzoom in Zoom Outzoom out
 5 / 16 page
background image
sames
RM2102DSE
5/16
http://www.sames.co.za
PRELIMINARY
SOLDERABLE SELECTOR SELECTION
Table 2: Jumper options
Name
These jumpers are used for calibration purposes. Also see "Calibrating the meter". Closing a
jumper will bypass the resistor in the resistor ladder.
Option
Description
J3 to J10
Closed
Leaving a jumper open will enable the resistor in the resistor ladder.
Open
Connecting to VSS will allow only negative energy to be measured.
J11
VSS
Connecting to VDD will allow only positive energy to be measured.
VDD
Connecting to jumper DIRO / DIRI will allow bi-directional energy measurement. (Bi-directional is
where both positive and negative energy is measured)
DIRO /
DIRI
Used to select the required rated conditions. See table 3 and 4 as well as figure 5 for further
details on the various settings available.
J14
VDD (+)
VSS
Used to select the required rated conditions. See table 3 and 4 as well as figure 5 for further
details on the various settings available.
J15
VDD (+)
VSS
Used to select the required rated conditions. See table 3 and 4 as well as figure 5 for further
details on the various settings available.
J16
VDD (+)
VSS
J18
VSS
Used to select between fast and normal pulse output mode on the calibration LED output. When connected to
VSS the normal pulse output mode is selected.
J17
VSS
Connecting to VDD selects the fast output pulse mode.
VDD (+)
When fast mode is selected this input can be used to enable or disable the internal pulse
stability circuitry for the LED output pulses. Connecting to VSS disables this circuitry.
J19
VSS (-)
Connecting to VDD enables this circuitry.
This selects the IC manufacturer’s test mode. For normal metering connect to VSS.
VDD (+)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com