2 / 12 page ![]() sames PM2005M/P 2/12 http://www.sames.co.za SETTING UP THE PM2005M/P MODULE JUMPER DESCRIPTION Power Supply Jumpers The power supply jumpers are used to disconnect the on- board power supply, allowing the metering section of the circuit to be powered from an external power supply if required. Jumper J4 J5 J6 J7 Description http://www.sames.co.za Voltage Selection Jumpers These jumpers are used to select between 115V and 230V operation. When closed the jumpers will half the series resistance in the voltage divider to the voltage sense inputs. Connects VDD to the metering circuitry. Connects VSS to the metering circuitry. GND connection point. Connection point between the power supply GND (N) and the SA2005 GND Module Setup Jumpers Setup for use with the SA2005M Please note that only one jumper should be closed at any one time. Closing more than one jumper may short circuit the power supply. The following jumpers (S1 and S9) are used to set the various dividing ratios, resolution and summing modes. Jumpers S1 to S3 set the rated conditions dividing ratio (pin RA of the SA2005M). Jumper J1 J2 J3 230V Open Open Open 115V Closed Closed Closed State Only S1 closed Only S2 closed Only S3 closed Description Select a multiplying ratio of 3/3 Select a ratio of 1/3 Select a ratio of 2/3 multiplying multiplying VDD VSS PH/DIR=100Hz Floating Voltage Level on Pin 7 of the SA2005 Select a 1252Hz pulse rate at rated input conditions S1, S2 and S3 open Jumpers S4 to S6 set the calibration LED resolution (dividing ratio) as well as the summing mode (pin RE of the SA2005M). Please note that only one jumper should be closed at any one time. Closing more than one jumper may short circuit the power supply. Jumpers S7 to S9 sets the dividing ratio (counter resolution, pin IM of the SA2005M) for the SA2005M’s motor drive output. Please note that only one jumper should be closed at any one time. Closing more than one jumper may short circuit the power supply. Set-up for use with the SA2005P Jumpers S1 to S9 must be removed (open), so as not to influence the functionality of the IIC bus operation. Jumper S10 may be used on certain IIC EEPROMS to protect the data written to the EEPROM. This jumper must be opened when programming the EEPROM. State Only S7 closed Only S8 closed Only S9 closed 1 (100 pulse/kWh) 100 10 Test Mode (1 pulse/kWh) (10 pulse/kWh) VDD VSS PH/DIR=100Hz Floating Voltage Level on Pin 9 of the SA2005 S7, S8 and S9 open Dividing ratio (counter resolution) State Only S4 closed Only S5 closed Only S6 closed Absolute sum Total sum Total sum Absolute sum VDD VSS PH/DIR=100Hz Floating Summing Mode S4, S5 and S6 open 4 1 4 1 LED dividing ratio Voltage Level on pin 8 of the SA2005 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |