| поискавой системы для электроныых деталей |
|
AD7322 датащи(PDF) 29 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD7322 датащи(HTML) 29 Page - Analog Devices |
|
29 / 37 page ![]() AD7322 Data Sheet Rev. B | Page 28 of 36 AUTOSHUTDOWN MODE (PM1 = 1, PM0 = 0) Once the autoshutdown mode is selected, the AD7322 auto- matically enters shutdown on the 15th SCLK rising edge. In autoshutdown mode, all internal circuitry is powered down. The AD7322 retains information in the registers during autoshutdown. The track-and-hold is in hold mode during autoshutdown. On the rising CS edge, the track-and-hold, which was in hold during shutdown, returns to track as the AD7322 begins to power up. The power-up from autoshutdown is 500 µs. When the control register is programmed to transition to autoshut- down mode, it does so on the 15th SCLK rising edge. Figure 47 shows the part entering autoshutdown mode. Once in autoshut- down mode, the CS signal must remain low to keep the part in autoshutdown mode. The AD7322 automatically begins to power up on the CS rising edge. The tPOWER-UP for autoshutdown is required before a valid conversion, initiated by bringing the CS signal low, can take place. When this valid conversion is complete, the AD7322 powers down again on the 15th SCLK rising edge. The CS signal must remain low again to keep the part in autoshutdown mode. AUTOSTANDBY MODE (PM1 = 0, PM0 = 1) In autostandby mode, portions of the AD7322 are powered down, but the on-chip reference remains powered up. The reference bit in the control register should be 1 to ensure that the on-chip reference is enabled. This mode is similar to auto- shutdown, but allows the AD7322 to power up much faster. This allows faster throughput rates to be achieved. As is the case with the autoshutdown mode, the AD7322 enters standby on the 15th SCLK rising edge when the control register is updated (see Figure 47). The part retains information in the registers during standby. Once in autostandby mode, the CS signal must remain low to keep the part in autostandby mode. The AD7322 remains in standby until it receives a CS rising edge. The ADC begins to power up on the CS rising edge. On the CS rising edge, the track-and-hold, which was in hold mode while the part was in standby, returns to track. The power-up time from standby is 750 ns. The user should ensure that 750 ns have elapsed before bringing CS low to attempt a valid conversion. Once this valid conversion is complete, the AD7322 again returns to standby on the 15th SCLK rising edge. The CS signal must remain low to keep the part in standby mode. Figure 47 shows the part entering autoshutdown mode. The sequence of events is the same when entering autostandby mode. In Figure 47, the power management bits are configured for auto- shutdown. For autostandby mode, the power management bits, PM1 and PM0, should be set to 0 and 1, respectively. CS 1 16 15 1 16 15 SCLK SDATA DIN VALID DATA VALID DATA DATA INTO CONTROL REGISTER DATA INTO CONTROL REGISTER tPOWER-UP CONTROL REGISTER IS LOADED ON THE FIRST 15 CLOCKS, PM1 = 1, PM0 = 0 PART ENTERS SHUTDOWN MODE ON THE 15TH RISING SCLK EDGE AS PM1 = 1, PM0 = 0 PART BEGINS TO POWER UP ON CS RISING EDGE THE PART IS FULLY POWERED UP ONCE tPOWER-UP HAS ELAPSED Figure 47. Entering Autoshutdown/Autostandby Mode |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |