| поискавой системы для электроныых деталей |
|
AD7787 датащи(PDF) 13 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD7787 датащи(HTML) 13 Page - Analog Devices |
|
13 / 20 page ![]() AD7787 Rev. 0 | Page 13 of 20 FILTER REGISTER (RS1, RS0 = 1, 0; POWER-ON/RESET = 0×04) The filter register is an 8-bit register from which data can be read or to which data can be written. This register is used to set the output word rate. Table 11 outlines the bit designations for the filter register. FR0 through FR7 indicate the bit locations, FR denoting the bits are in the filter register. FR7 denotes the first bit of the data stream. The number in the parenthesis indicates the power-on/reset default status of that bit. FR7 FR6 FR5 FR4 FR3 FR2 FR1 FR0 0 (0) 0 (0) CDIV1 (0) CDIV0 (0) 0 (0) FS2 (1) FS1 (0) FS0 (0) Table 11. Filter Register Bit Designations Bit Location Bit Name Description FR7 to FR6 0 These bits must be programmed with a Logic 0 for correct operation. FR5 to FR4 CLKDIV1 to CDIV0 These bits are used to operate the AD7787 in the lower power modes. The clock is internally divided and the power is reduced. In the low power modes, the update rates will scale with the clock frequency so that dividing the clock by 2 causes the update rate to be reduced by a factor of 2 also. 00 Normal Mode 01 Clock Divided by 2 10 Clock Divided by 4 11 Clock Divided by 8 FR3 0 This bit must be programmed with a Logic 0 for correct operation. FR2 to FR0 FS2 to FS0 These bits set the output word rate of the ADC. The update rate influences the 50 Hz/60 Hz rejection and the noise. Table 12 shows the allowable update rates when normal power mode is used. In the low power modes, the update rate is scaled with the clock frequency. For example, if the internal clock is divided by a factor of 2, the corresponding update rates are divided by 2 also. Table 12. Update Rates FS2 FS1 FS0 fADC (Hz) f3dB (Hz) RMS Noise (µV) Rejection 0 0 0 120 28 40 25 dB @ 60 Hz 0 0 1 100 24 25 25 dB @ 50 Hz 0 1 0 33.3 8 3.36 0 1 1 20 4.7 1.6 80 dB @ 60 Hz 1 0 0 16.6 4 1.5 65 dB @ 50 Hz/60 Hz (Default Setting) 1 0 1 16.7 4 1.5 80 dB @ 50 Hz 1 1 0 13.3 3.2 1.2 1 1 1 9.5 2.3 1.1 67 dB @ 50 Hz/60 Hz DATA REGISTER (RS1, RS0 = 1, 1; POWER-ON/RESET = 0×000000) The conversion result from the ADC is stored in this data register. This is a read-only register. On completion of a read operation from this register, the RDY bit/pin is set. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |