| поискавой системы для электроныых деталей |
|
REM1 датащи(PDF) 4 Page - Recom International Power |
|
|
|||||||||||||||||||||||||||||
REM1 датащи(HTML) 4 Page - Recom International Power |
|
4 / 5 page ![]() DC/DC Converter MED-4 REV.: 2/2017 www.recom-power.com Specifications (measured @ ta= 25°C, nominal input voltage, full load and after warm-up) REM1 Series ENVIRONMENTAL Parameter Condition Value Operating Temperature Range without derating (see graph) -40°C °C to +85°C Maximum Case Temperature 105°C Temperature Coefficient 0.02%/°C typ. Operating Altitude according to IEC/EN60601-1 accroding to IEC/EN62368-1 3000m 5000m Operating Humidity non-condensing 5% - 95% RH max. Pollution Degree PD2 MTBF according to MIL-HDBK-217F, G.B. +25°C +85°C 18200 x 103 hours 7500 x 103 hours Vibration according to MIL-STD-202G standard 100 120 80 85 90 60 40 20 0 -20 -40 0 20 30 40 60 80 100 Ambient Temperature [°C] Derating Graph (@ chamber and natural convection 0.1m/s) SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Standard Audio/video, information and communication technology equipment. Safety requirements (CB Scheme) L0339m31-A-L EN62368-1:2014 Medical Electric Equipment, General Requirements for Saftey and Essential Performance E314885-D1000-1/A0/C0-UL ANSI/AAMI ES60601-1:2012 + A2 2010/2012 CSA C22.2 No. 60601-1:14, 3rd Edition, 2014 Medical Electric Equipment, General Requirements for Safety and Essential Performance E314885-D1000-1/A0/C0-CB IEC60601-1:2005 +AM1:2012 EN60601-1:2006 + A12:2014 RoHs2+ RoHS-2011/65/EU + AM-2015/863 EMC Compliance Condition Standard / Criterion Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility IEC60601-1-2:2014 EN60601-1-2:2015 Industrial, scientific and medical equipment - Radio frequency disturbance characteristics - Limits and methods of measurement with external filter EN55011, 2009+A1:2010, Class B ESD Electrostatic discharge immunity test air: ±15kV; contact: ±8kV IEC61000-4-2:2008 , Criteria A Radiated, radio-frequency, electromagnetic field immunity test 3V/m IEC61000-4-3:2006+A2:2010, Criteria A Fast Transient and Burst Immunity DC port: ±2kV IEC61000-4-4:2012, Criteria A Surge Immunity DC port: ±1kV IEC61000-4-5:2014, Criteria B Immunity to conducted disturbances, induced by radio-frequency fields DC port: 6V IEC61000-4-6:2013, Criteria A Power Magnetic Field Immunity 50Hz, 30A/m IEC61000-4-8:2009, Criteria A continued on next page |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |