Back Button LTC1966CMS8 Datasheet HTML 17Page - Linear Technology LTC1966CMS8 Datasheet HTML 18Page - Linear Technology LTC1966CMS8 Datasheet HTML 19Page - Linear Technology LTC1966CMS8 Datasheet HTML 20Page - Linear Technology LTC1966CMS8 Datasheet HTML 21Page - Linear Technology LTC1966CMS8 Datasheet HTML 22Page - Linear Technology LTC1966CMS8 Datasheet HTML 23Page - Linear Technology LTC1966CMS8 Datasheet HTML 24Page - Linear Technology LTC1966CMS8 Datasheet HTML 25Page - Linear Technology Next Button
Zoom Inzoom in Zoom Outzoom out
 21 / 32 page
background image
21
LTC1966
sn1966 1966fas
frequency. So with AC + DC waveforms, the required
value for CAVE should be based on half of the lowest input
frequency, using the same design curves presented in
Figures 6, 8, 17 and 18.
Crest factor, which is the peak to RMS ratio of a dynamic
signal, also effects the required CAVE value. With a higher
crest factor, more of the energy in the signal is concentrated
into a smaller portion of the waveform, and the averaging
has to ride out the long lull in signal activity. For busy
waveforms, such as a sum of sine waves, ECG traces or
SCR-chopped sine waves, the required value for CAVE
should be based on the lowest fundamental input frequency
divided as such:
f
f
CF
DESIGN
INPUT MIN
=
()
•–
32
APPLICATIO S I FOR ATIO
using the same design curves presented in Figures 6, 8,
17 and 18. For the worst case of square top pulse trains,
that are always either zero volts or the peak voltage, base
the selection on the lowest fundamental input frequency
divided by twice as much:
f
f
CF
DESIGN
INPUT MIN
=
()
•–
62
The effects of crest factor and DC offsets are cumulative.
So for example, a 10% duty cycle pulse train from 0VPEAK
to 1VPEAK (CF = √10 = 3.16) repeating at 16.67ms (60Hz)
input is effectively only 30Hz due to the DC asymmetry and
is effectively only:
fHz
DESIGN ==
30
6
3 16
2
378
•.
–
.
for the purposes of Figures 6, 8, 17 and 18.
Figure 20. Settling Time with DC-Accurate Post Filter
Figure 19. Settling Time with Buffered Post Filter
SETTLING TIME (SEC)
0.01
0.1
1
10
1
0.1
10
100
1066 F14
C = 100
µF
C = 47
µF
C = 22
µF
C = 10
µF
C = 4.7
µF
C = 2.2
µF
C = 1.0
µF
C = 0.47
µF
C = 0.22
µF
C = 0.1
µF
SETTLING TIME (SEC)
0.01
0.1
1
10
1
0.1
10
100
1066 F20
C = 100
µF
C = 47
µF
C = 22
µF
C = 10
µF
C = 4.7
µF
C = 2.2
µF
C = 1.0
µF
C = 0.47
µF
C = 0.22
µF
C = 0.1
µF



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com