| поискавой системы для электроныых деталей |
|
AD7734 датащи(PDF) 24 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD7734 датащи(HTML) 24 Page - Analog Devices |
|
24 / 32 page ![]() AD7734 Rev. 0 | Page 24 of 32 Dump Mode When the DUMP bit in the mode register is set to 1, the channel status register will be read immediately by a read of the channel data register, regardless of whether the status or the data register has been addressed through the communications register. The DIN pin should not be high while reading 24-bit data in dump mode; otherwise, the AD7734 will be reset. Figure 18 shows the digital interface signals executing a single conversion on Channel 0, waiting for the RDY pin to go low, and reading the Channel 0 status register and data register in the dump mode. Continuous Conversion Mode When the mode register is being written, the ADC status byte is cleared and the RDY pin goes high, regardless of its previous state. When the continuous conversion command is written to the mode register, the ADC starts conversion on the channel selected by the address of the mode register. After the conversion is complete, the relevant channel data register and channel status register are updated, the relevant RDY bit in the ADC status register is set, and the AD7734 continues converting on the next enabled channel. The part will cycle through all enabled channels until put into another mode or reset. The cycle period will be the sum of all enabled channels’ conversion times, set by the corresponding channel conversion time registers. The RDY bit is reset when the relevant channel data register is being read. The behavior of the RDY pin depends on the RDYFN bit in the I/O port register. When the RDYFN bit is 0, the RDY pin goes low when any channel has unread data. When the RDYFN bit is set to 1, the RDY pin will only go low if all enabled channels have unread data. If an ADC conversion result has not been read before a new ADC conversion is completed, the new result will overwrite the previous one. The relevant RDY bit goes low and the RDY pin goes high for at least 163 MCLK cycles (~26.5 µs), indicating when the data register is updated, and the previous conversion data is lost. If the data register is being read as an ADC conversion completes, the data register will not be updated with the new result (to avoid data corruption) and the new conversion data is lost. Figure 19 shows the digital interface signal’s sequence for the continuous conversion mode with Channels 0 and 1 enabled and the RDYFN bit set to 0. The RDY pin goes low and the data register is read after each conversion. Figure 20 shows a similar sequence but with the RDYFN bit set to 1. The RDY pin goes low and all data registers are read after all conversions are completed. Figure 21 shows the RDY pin when no data are read from the AD7734. DIN SCLK CS DOUT WRITE COMMUNICATIONS REGISTER WRITE MODE REGISTER RDY CONVERSION TIME READ DATA REGISTER READ CHANNEL STATUS 38h 48h 48h WRITE COMMUNICATIONS REGISTER (00h) (00h) (00h) STATUS DATA DATA Figure 18. Serial Interface Signals—Single Conversion Command, 16-Bits Data Reading, Dump Mode SERIAL INTERFACE START CONTINUOUS CONVERSION RDY CH0 CONVERSION READ DATA CH1 CH1 CONVERSION CH0 CONVERSION READ DATA CH0 CH1 CONVERSION READ DATA CH0 CH0 CONVERSION READ DATA CH1 Figure 19. Continuous Conversion, CH0 and CH1, RDYFN = 0 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |