352 / 670 page ![]() AN1097 3–206 Motorola Sensor Device Data www.motorola.com/semiconductors The result is twice a differential conversion. As demonstrated below, all errors from the instrument amplifier are cancelled. Other averaging techniques may be used to improve the result, but the appropriated algorithm is always determined by the maximum bandwidth of the input signal and the required accuracy of the system. 1 2 4 3 PRESSURE SENSOR SYSTEM MPX2100AP MC74HC4053 + 5 V I/O 0 V V1 Rf Rg Rf V2 MC68HC05B6 CH1 P CH2 VRH VDD VRL VSS Figure 9. Two Channel Input and One Output Port Are Used by the MCU MC33078 + – + – SYSTEM CALCULATION Sensor out 2 Sensor out 4 Vs2 = a (P) + of2 Vs4 = b (P) + of4 Amplifier out 1 Amplifier out 2 V1 = Avd (Vs2 + OF1) V2 = Avd (Vs4 + OF2) Inverting of the amplifier input V1x = Avd (Vs4 + OF1) V2x = Avd (Vs2 + OF2) Delta = V1–V2 1st differential result = Avd * (Vs2 of OF1) – Avd * (Vs4 + OF2) Deltax = V2x–V1x 2nd differential result = Avd * (Vs2 + OF2) – Vdc * (Vs4 + OF1) Adding of the two differential results VoutV = Delta + Deltax = Avd*Vs2 + Avd*OF2 + Avd*OF2 – Avd*OF1 = 2 * Avd * (Vs2 –Vs4) = 2 * Avd * [(a (P) + of2) – (b (P) + of4)] = 2 * Avd * [V(P) + Voffset] + Avd*OF1 – Avd*OF2 + Avd*OF2 – Avd*OF1 There is a full cancellation of the amplifier offset OF1 and OF2. The addition of the two differential results V1–V2 and V2x–V1X produce a virtual output voltage VoutV which becomes the applied input voltage to the A/D converter. The result of the conversion is expressed in the number of counts or bits by the ratiometric formula shown below: count = VoutV * 255 VRH–VRL 255 is the maximum number of counts provided by the A/D converter and VRH–VRL is the reference voltage of the ratiometric A/D converter which is commonly tied to the 5.0 V supply voltage of the MCU. When the tolerance of the full scale pressure has to be in the range of ± 2.5%, the offset of the pressure sensor may be neglected. That means the system does not require any calibration procedure. The equation of the system transfer is then: count = 2 * Avd * V(P) * 51/V where: Avd is the differential–mode gain of the instrument amplifier which is calculated using the equation (1). Then with Rf = 510 k Ω and Rg = 9.1 kΩ Avd = 113. The maximum counts available in the MCU register at the Full Scale Pressure is: count (Full Scale) = 2 * 113 * 0.02 V * 51/V = 230 knowing that the MPX2100AP pressure sensor provides 20 mV at 5.0 excitation voltage and 100 kPa full scale pressure. The system resolution is 100 kPa/230 that give 0.43 kPa per count. MC68HC05B6 VRH CH1 P CH2 VRL VSS VDD + 5 V 0 V I/O FINE CAL. Figure 10. Full Scale Output Calibration Using the Reference Voltage VRH–VRL Freescale Semiconductor, Inc. For More Information On This Product, Go to: www.freescale.com |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |