347 / 670 page ![]() AN1082 3–201 Motorola Sensor Device Data www.motorola.com/semiconductors 4 2 3 6 Figure 1. Demo Kit with 4 – 20 mA Current Loop R4 VCC = +15 Volts dc C1 C2 R8 R9 RL R7 R6 R3 R5 R12 R10 R11 Roff OFFSET ADJUST a 3 2N2222 + – – – + + + a 1 a 2 4 7 R2 R1 5 8 1 2 3 RG gain adj. 1 MPX2100DP output Basic Circuit of SEK–1 Additional Circuit for 4 to 20 mA current loop (Receiver Load Resistance : RL = 150 to 400 Ohms) RG = 47 K Pot. R7 = 1 K Roff = 1 M Pot. R10 = 110 K * R1 = R2 = 330 K R11 = 1 M * R3 = R4 = 27 K R12 = 330 K * R5 = R6 = 27 K C1 = C2 = 0.1 µF * R8 = R9 = 150 a1, a2, a3 = 1/4 MC33079 * All resistor pairs must be matched at better than 0.5% Note A: If using SEK–1 a1, a2, a3 = 1/2 MC33078 Note A: RG from 20 K to 47 K Note A: R1 and R2 from 1M to 330 K NOTICE: THE PRESSURE SENSOR OUTPUT IS RATIOMETRIC TO THE POWER SUPPLY VOLTAGE. THE OUTPUT WILL CHANGE WITH THE SAME RATIO AS VOLTAGE CHANGE. Remote Receiver – The output is ratiometric to the power supply voltage. For example, if the receiver reads 18 mA at 80 kPa and 15 V power supply, the receiver should read 16.8 mA under the same pressure with 14 V power supply. For best results it is mandatory to use a regulated power supply. If that is not possible, the circuit must be modified by inserting a 12 V regulator to provide a constant supply to the pressure sensor. When using a Motorola MC78L12AC voltage regulator, the circuit can be used with power voltage variation from 14 to 30 volts. The following results have been achieved using an MPX2100DP and two MC33078s. The resistors were regular carbon resistors, but pairs were matched at ± 0.3% and capacitors were 0.1 µF. The load was 150 ohms and the transmission line was a two pair telephone line with the +15 Vdc power supply connected on the remote receiver side. Note: Best performances in temperature can be achieved using metal film resistors. The two potentiometers must be chosen for high temperatures up to 125 °C. The complete circuit with pressure sensor is available under reference TZA120 and can be ordered as a regular Motorola product for evaluation. Freescale Semiconductor, Inc. For More Information On This Product, Go to: www.freescale.com |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |