4 / 27 page ![]() CP20.241, CP20.241-C1, CP20.241-S1, CP20.241-S2 CP-Series 24V, 20A, SINGLE PHASE INPUT May 2017 / Rev. 0.3 DS-CP20.241-EN All parameters are typical values specified at 24V, 20A output, 230Vac input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany P R E L I M I N A R Y 3. AC-INPUT AC input nom. AC 100-240V Suitable for TN-, TT- and IT mains networks AC input range min. 85-264Vac Continuous operation min. 264-300Vac < 500ms Allowed voltage L or N to earth max. 300Vac Continuous, IEC 62103 Input frequency nom. 50–60Hz ±6% Turn-on voltage typ. 82Vac Steady-state value, see Fig. 3-1 Shut-down voltage typ. 72Vac Steady-state value, see Fig. 3-1 External input protection See recommendations in chapter 24.3. AC 100V AC 120V AC 230V Input current typ. 5.15A 4.26A 2.23A At 24V, 20A, see Fig. 3-3 Power factor*) typ. 0.996 0.996 0.980 At 24V, 20A, see Fig. 3-4 Crest factor**) typ. 1.65 1.63 1.63 At 24V, 20A Start-up delay typ. 450ms 420ms 440ms See Fig. 3-2 Rise time typ. 45ms 45ms 45ms At 24V, 20A const. current load, 0mF load capacitance, see Fig. 3-2 typ. 90ms 90ms 90ms At 24V, 20A const. current load, 20mF load capacitance,, see Fig. 3-2 Turn-on overshoot max. 200mV 200mV 200mV See Fig. 3-2 *) The power factor is the ratio of the true (or real) power to the apparent power in an AC circuit. **) The crest factor is the mathematical ratio of the peak value to RMS value of the input current waveform. Fig. 3-1 Input voltage range Fig. 3-2 Turn-on behavior, definitions 85V Rated input range max. 500ms V IN P OUT 300Vac 264V Start-up delay Rise Time - 5% Output Voltage Input Voltage Fig. 3-3 Input current vs. output current at 24V output voltage Fig. 3-4 Power factor vs. output current at 24V output voltage 24A 2468 10 12 14 16 18 0 1 2 3 4 5 6A Input Current, typ. 20 22 a) 100Vac b) 120Vac c) 230Vac b a c Output Current Power Factor, typ. 2 4 6 8 10 12141618 24A 0.75 0.8 0.85 0.9 0.95 1.0 20 22 a) 100Vac b) 120Vac c) 230Vac a, b c Output Current 4/27 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |