| поискавой системы для электроныых деталей |
|
WM9705 датащи(PDF) 44 Page - Wolfson Microelectronics plc |
|
|
|||||||||||||||||||||||||||||
WM9705 датащи(HTML) 44 Page - Wolfson Microelectronics plc |
|
44 / 55 page ![]() WM9705 Production Data w PD Rev 4.0 December 2003 44 POLLING METHOD The polling method relies on the controller to instruct every operation, i.e. to send an instruction requesting every individual conversion specifically. A polled conversion is requested by writing a 1 to POLL bit 15 in register 76h, along with the address of the channel to be converted. The channel to convert is identified by a 3-bit tag word ADR[2-0] written to the Pen control register 76h. This tag has the same value as the value read back with the conversion result, thus identifying which channel the result is for, see Table 24. If ADD[2-0] is set to 0 then no conversion will take place and POLL will be reset. If the channel to convert is an X or Y pen channel, then the appropriate screen driver switch configuration is selected first, the screen allowed to settle for a time (selected by programming the value into the DELAY register, DEL[3-0] in register 76h) and then the screen sample taken and the conversion made. Figures A2 and A3 show the switch configurations for X and Y plate conversions. Once the conversion is complete, the result is written into the results register 7Ah where it is available for readback. Figure 21 Control of ADC conversions : Polling Method CO-ORDINATE METHOD Setting bit COO in register 76h puts the device into Co-ordinate conversion mode. Co-ordinate method of conversion instructs a sequence of conversions necessary to perform a pen co-ordinate determination. Most basically this requires an X and a Y conversion but may also include a pressure measurement. Writing to the POLL bit with COO bit in register 76h set initiates a set of co-ordinate conversions, the results of which are returned to the controller as soon as they are available. If pressure conversion, or an auxiliary conversion are also required as part of the sequence, this is instructed by writing the appropriate address into the ADR [2-0] bits of register 76h. (X and Y addresses do not need to be set in this case, as they are implied by the choice of co-ordinate method of operation). DEL[3-0] delays are applied as for polled operation to all conversions. Subsequent POLL operations will then return both X and Y conversion results, plus the auxiliary or pressure conversion result indicated by the value set in ADR[2-0]. Once a conversion is complete, the result is written into the results register 7Ah where it is available for readback. Screen Switch / Input Mux mode EAPD/BUSY delay = 2 frames Single coordinate conversion with ADR = 000 (X and Y only) with delay set to 1 (2 frames) POLL SYNC ADR = 001 - X measurement ADR = 010 - Y measurement DELAY CONVERT DELAY CONVERT ADC MODE Pen Detect or Off X X Write to 0x76 with 0x8810 SDOUT Pen Detect or Off delay = 2 frames PENDATA X X measurement data Y measurement data external signals internal signals |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |