15 / 31 page ![]() DocID025703 Rev 2 15/31 VIPER38 Operation 31 The following formula can be used for the CVDD capacitor calculation: Equation 1 The parameter tSSaux is the time needed for the steady state of the auxiliary voltage. This time represents an estimate of the user’s application according to the output stage configurations (transformer, output capacitances, etc.). During the converter startup time, the drain current limitation is progressively increased to the maximum value. In this way the stress on the secondary diode is considerably reduced. It also helps to prevent transformer saturation. The soft-start time lasts 8.5 ms and the feature is implemented for every attempt of the startup converter or after a fault. Figure 17. IDD current during startup and burst mode C VDD I DDch1 t SSaux × V DDon V DDoff – ----------------------------------------- = |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|