P6002ACMC датащи(PDF) 144 Page - Teccor Electronics |
|
|
|||||||||||||||||||||||||||||
P6002ACMC датащи(HTML) 144 Page - Teccor Electronics |
|
144 / 212 page ![]() UL 60950 3rd Edition (formerly UL 1950, 3rd edition) http://www.teccor.com 4 - 20 © 2002 Teccor Electronics +1 972-580-7777 SIDACtor® Data Book and Design Guide Overvoltage Flowchart The overvoltage flowchart in Figure 4.5 shows specific guidelines for determining overvoltage requirements applicable to specific designs. Figure 4.5 Overvoltage Flowchart No No No No No Yes 100 A2-S Limiting1 No Overvoltage Testing Connects to Outside Cable Yes Yes 1.3 A Limiting2 26 AWG Line Cord3 Yes Pass 1 Yes Pass 6.1.24 Fire Enclosure and Spacings5 Yes Yes Acceptable Fire Enclosure No No Yes Pass 5 Pass 26 Pass 3, 47 Yes No No No Yes Not Acceptable Notes: 1. Current Limiting — Equipment that has a method for limiting current to an I2t rating of 100A2s 2. Current Limiting — Equipment that has a method for limiting current to 1.3 A max steady state 3. 26 AWG Line Cord — Minimum 26 American Wire Gauge (AWG) telecommunications line cord either supplied with the equipment or described in the safety instructions 4. Clause 6.3.3 — The telephone line must be adequately isolated from earth for the operating mode being considered and at a voltage of 120 V rms. Refer to Section 6.1.2 of UL 60950. 5. Fire Enclosure and Spacing — Fire enclosures minimize fire hazards by containing any emission of flame, molten metal, flaming drops, or glowing particles that could be emitted by the equipment under fault conditions. Fire enclosure construction is covered in Section 4.4.6 of UL 60950. Spacing applies to parts in the TNV circuits that might ignite under overvoltage conditions. Spacing requirements mandate that parts be separated from internal materials of flammability class V-2 or lower, by at least 25 mm of air or a barrier material of flammability class V-1 or better. Parts also should be separated from openings in the top or sides of the enclosure by at least 25 mm of air or a material barrier. 6. Test Condition 2 is not required for equipment with 1.3 A limiting. 7. Test Conditions 3 and 4 are not required for connections limited to outside cable less than 1,000 m. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |