| поискавой системы для электроныых деталей |
|
P6002ACMC датащи(PDF) 141 Page - Teccor Electronics |
|
|
|||||||||||||||||||||||||||||
P6002ACMC датащи(HTML) 141 Page - Teccor Electronics |
|
141 / 212 page ![]() UL 60950 3rd Edition (formerly UL 1950, 3rd edition) © 2002 Teccor Electronics 4 - 17 http://www.teccor.com SIDACtor® Data Book and Design Guide +1 972-580-7777 UL 60950 Terminology The following definitions assist in understanding UL 60950: Creepage distance is the shortest distance between two conductors, measured along the surface of the insulation. DC voltages shall be included in determining the working voltage for creepage distances. (The peak value of any superimposed ripple or short disturbances, such as cadenced ringing signals, shall be ignored.) Clearance distance is the shortest distance between two conductive parts or between a conductive part and the outer surface of the enclosure measured through air. DC voltages and the peak value of any superimposed ripple shall be included in determining the working voltage for clearance distances. Creepage and clearance distances are also subject to the pollution degree of the equipment: • Pollution degree 1 — components and assemblies that are sealed to prevent ingress of dust and moisture • Pollution degree 2 — generally applicable to equipment covered by UL 60950 • Pollution degree 3 — equipment is subject to conductive pollution or to dry non- conductive pollution, which could become conductive due to expected condensation. To ensure safe operating conditions of the equipment, UL 60950 focuses on the insulation rating of the circuit(s) under consideration. Table 4.15 and Table 4.16 indicate the required creepage and clearance distances depending on material group, pollution degree, working voltage, and maximum transient voltage in the secondary circuit. For a typical telecommunication application with a working voltage of 200 V, pollution degree 2, material group IIIb, the creepage distance is 2 mm. The clearance distance is 2 mm for reinforced insulation. SELV Secondary circuit whose voltage values do not exceed a safe value (voltage less than hazardous levels of 42.4 V peak or 60 V dc) TNV Telecommunication Network Voltage (a secondary circuit) TNV3 ³ SELV but with exposure to surges TNV2 ³ SELV but without exposure to surges TNV1 £ SELV with exposure to surges |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |