поискавой системы для электроныых деталей
  Russian  ▼
ALLDATASHEETRU.COM

X  

AMM-2F датащи(PDF) 1 Page - Gamewell-FCI by Honeywell

номер детали AMM-2F
подробное описание детали  Addressable Monitor Module
PDF  1 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
производитель  GAMEWELL-FCI [Gamewell-FCI by Honeywell]
домашняя страница  http://www.gamewell-fci.com
Logo GAMEWELL-FCI - Gamewell-FCI by Honeywell

AMM-2F датащи(HTML) 1 Page - Gamewell-FCI by Honeywell

  AMM-2F_13 Datasheet HTML 1Page - Gamewell-FCI by Honeywell  
Zoom Inzoom in Zoom Outzoom out
 1 / 1 page
background image
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118
Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.
©2013 Honeywell International Inc. All rights reserved.
www.gamewell-fci.com
9020-0626 Rev. E page 1 of 1
Velociti® Series
AMM-2F
Addressable Monitor Module
Description
Velociti® is a registered trademark of Honeywell International Inc.
UL® is a registered trademark of Underwriters Laboratories Inc.
The Gamewell-FCI Velociti® Series, addressable
monitor module AMM-2F is a single Style B, Class B
initiating device circuit (IDC) with a 47KW end-of-line
resistor. This module provides an address for any
device or group of devices connected to this circuit
on the signaling line circuit (SLC) of the Gamewell-
FCI addressable series fire alarm control panel. Any
initiating device with normally open (N.O.) dry con-
tacts may be made addressable when connected to
the AMM-2F module.
The Velociti® Series use a communication protocol
that substantially increases the speed of communi-
cation between the sensors and certain Gamewell-
FCI analog addressable fire alarm controls. These
devices operate in a grouped fashion. If one of the
devices in the group has a status change, the
panel’s microprocessor stops the group poll and
concentrates on the single device. The net effect is
response speed up to five times greater than earlier
designs.
The AMM-2F module can be programmed to provide
a wide variety of input functions to the Gamewell-FCI
addressable series fire alarm control panels. It can
be identified as a manual station, heat detector, ple-
num detector, waterflow switch, tamper switch, N.O.
contact, smoke detector, projected beam smoke
detector, sub loop, remote zone, etc. It can also
serve as a remote system silence, system reset,
system acknowledge or drill switch. It is even possi-
ble to customize its device type to meet specific job
requirements.
The initiating device circuit of the AMM-2F can sup-
port a maximum line resistance of up to 40 ohms
allowing the use of linear heat detection devices. The
compact size facilitates the installation of the module
inside manual stations, or mounting boxes of various
types of alarm initiating devices.
Features
Compact size allows easy installation
Class B, Style B, initiating circuit
40 Ohm line resistance for each initiating device circuit
Connects to any normally open dry contact device
Specifications
Supervisory Current:
.000375 amps
Alarm Current:
.00060 amps
Operating Temperature: 32° to 120° F (0° to 49° C)
Relative Humidity:
10 to 93%
(non-condensing)
End-of-Line Resistance: 47K ohms
Dimensions:
1.3” L x 2.5” W x 0.5” D
(3.3 x 6.4 x 1.3 cm)
Ordering Information
Part Number
Description
AMM-2F
Addressable monitor module, single
circuit, Style B, Class B
AMM-2F
7300-1703:0102
3023594
227-03-E VOL IV
MEA
Approved
S1949
SIGNALING
APPROVED
FM


Аналогичный номер детали - AMM-2F_13

производительномер деталидатащиподробное описание детали
logo
Gamewell-FCI by Honeywe...
AMM-2F GAMEWELL-FCI-AMM-2F Datasheet
428Kb / 1P
Addressable monitor module, single circuit, Style B, Class B
More results

Аналогичное описание - AMM-2F_13

производительномер деталидатащиподробное описание детали
logo
List of Unclassifed Man...
SSC-CMX2 ETC2-SSC-CMX2 Datasheet
249Kb / 1P
Clip Addressable Output Module
logo
Gamewell-FCI by Honeywe...
AMM-2F GAMEWELL-FCI-AMM-2F Datasheet
428Kb / 1P
Addressable monitor module, single circuit, Style B, Class B
AMM-4SF GAMEWELL-FCI-AMM-4SF Datasheet
195Kb / 1P
Addressable monitor module, single circuit,
AAM95 GAMEWELL-FCI-AAM95 Datasheet
99Kb / 2P
Analog Addressable Module
AM500 GAMEWELL-FCI-AM500 Datasheet
328Kb / 2P
Addressable Module
SCM-SS GAMEWELL-FCI-SCM-SS Datasheet
456Kb / 6P
Six-Circuit Addressable Control Module
logo
Linear Technology
LTC6802-2 LINER-LTC6802-2 Datasheet
374Kb / 34P
Multicell Addressable Battery Stack Monitor
LTC6802-2 LINER-LTC6802-2_15 Datasheet
378Kb / 34P
Multicell Addressable Battery Stack Monitor
logo
Gamewell-FCI by Honeywe...
ASM-16 GAMEWELL-FCI-ASM-16_13 Datasheet
57Kb / 1P
ASM-16 Addressable Switch Module
AMM-4F GAMEWELL-FCI-AMM-4F_13 Datasheet
67Kb / 1P
Addressable Monitor Module
More results


Html Pages

1


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com