| поискавой системы для электроныых деталей |
|
SLAD4.100 датащи(PDF) 2 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
SLAD4.100 датащи(HTML) 2 Page - PULS GmbH |
|
2 / 4 page ![]() 2/ 4 slad4e100 / 071026 SLAD4.100 Data sheet Efficiency, Reliability Operating and environmental data Efficiency typ. 90.5% (input 24Vdc, output 4A) , see Fig. 4 Power dissipation typ. 12.7W (input 24Vdc, output 4A), see Fig. 5 Non-operating temperature range -40°C up to +85°C Operating temperature range -25°C up to +70°C (measured at 25mm below the unit) Derating from 60°C 3W/K onwards, power reduction necessary, see Fig. 6 Cooling natural convection, no forced air-cooling necessary Over-temperature protection Yes, output shutdown with automatic restart Humidity protect from moisture and condensation Vibration sinusodial 2-17.8Hz: ±1.6mm; 17.8-500Hz: 2g; 2 hours / axis; IEC 60068-2-6 Shock 30g 6ms, 20g 11ms 3 bumps / direction, 18 bumps in total; IEC 60068-2-27 Degree of pollution 2 ( EN 60950-1) Overvoltage category II ( IEC 60950-1) III ( IEC 62103) Electromagnetic Compatibility (EMC) Emissions EN 61000-6-3 (also includes EN 61000-6-4) Class B (EN 55011, EN 55022) Immunity EN 61000-6-2 (also includes EN 61000-6-1) Electrostatic Discharge EN 61000-4-2 Contact discharge Air discharge 8kV 15kV Criterion A Criterion A Electromagnetic RF fields EN 61000-4-3 80MHz-2.7GHz 10V/m Criterion A Fast transients (Burst) EN 61000-4-4 Input lines Output lines 2kV 4kV Criterion A Criterion A Surge voltage on input EN 61000-4-5 + - + / - chassis ground 1kV 2kV Criterion A Criterion A Surge voltage on output EN 61000-4-5 + - + / - chassis ground 500V 500V Criterion A Criterion A Conducted disturbance EN 61000-4-6 0,15-80MHz 10V Criterion A Criterions: A: DC/DC converter shows normal operation behavior within the defined limits. C: Temporary loss of function is possible. DC/DC converter might shut-down and restarts by itself. No damage or hazards will occur to the DC/DC converter. Schematic Input Fuse & Input Filter Power Converter Output Filter Output Over- Voltage Protection Reverse Polarity Protection & Inrush Limiter Chassis Ground + - Over- Temperature Protection AS-i ok (green) AS-i + AS-i + Shield AS-i - AS-i - AS-i Decoupling Unit Fig.1 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |