8 / 14 page ![]() www.sensirion.com Version 0.5 – January 2017 8/14 5.3.3 Triggered Measurement During a triggered measurement the sensor measures both differential pressure and temperature. The measurement starts directly after the command has been sent. The command needs to be repeated with every measurement. Command code (Hex) Temperature compensation Clock stretching 0x3624 Mass flow 0x3726 Mass flow Yes 0x362F Differential pressure 0x372D Differential pressure Yes During the 45ms that the sensor is measuring, no command can be sent to the sensor. After the 45ms the result can be read out and any command can be sent to the sensor. Monitoring whether or not the sensor is ready with its measurement can be done with the following methods. Method Available Description Clock stretching Only for clock stretching commands The sensor starts the measurement after the triggered measurement command with clock stretching. When an I2C read header is sent within 45ms the sensor performs clock stretching after acknowledging the read header. When the sensor has finished the measurement, it makes the result available by releasing the SCL. Polling Only for non-clock stretching commands In this mode the sensor does not acknowledge (NACK) an I2C read header as long as no measurement result is available. When new measurement data is available it can be read out by sending an I2C read header and reading out the data from the sensor. In the table below the data layout of the results can be found. Preceding command Consecutive read Description Triggered measurement Byte1: DP 8msb Byte2: DP 8lsb Byte3: CRC Byte4: Temp 8msb Byte5: Temp 8lsb Byte6: CRC Byte7: Scale Factor differential pressure 8msb Byte8: Scale Factor differential pressure 8lsb Byte9: CRC After a triggered measurement command, the results can be read out when the sensor is finished with the measurement. The temperature and scale factor don’t need to be read out (every time). The read sequence can be aborted by a NACK and a STOP condition. 5.3.4 Soft Reset Command I2C address + W bit + command code (Hex) Consecutive read Description General call reset 0x0006 NA This sequence resets the sensor with a separate reset block, which is as much as possible detached from the rest of the system on chip. Note that the I2C address is 0x00, which is the general call address, and that the command is 8 bit. The reset is implemented according to the I2C specification. After the reset command the sensor will take maximum 2ms to reset. During this time the sensor will not acknowledge its address nor accept commands. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |