7 / 14 page ![]() www.sensirion.com Version 0.8 – January 2017 7/14 5.3.1 Start Continuous Measurement The sensor measures both the differential pressure and temperature. Both measurement results can be read out through one single I2C read header. Continuous measurements can be started up in different configurations by a set of commands. Command code (Hex) Temperature compensation Averaging 0x3603 Mass flow Average till read 0x3608 Mass flow None - Update rate 1ms 0x3615 Differential pressure Average till read 0x361E Differential pressure None - Update rate 1ms After one of the commands has been sent, the chip continuously measures and updates the measurement results. New results can be read continuously with only an I2C read header. (Measurement) commands must not be sent until the stop measurement command has been sent. After the start measurement command is sent: - the first measurement result is available after 8ms;. - small accuracy deviations (%mv) can occur during the next 12ms. When no measurement data is yet available the sensor will respond with a NACK to the I2C read header (I2C address + read bit). Preceding command Consecutive read Description continuous measurement Byte1: Differential Pressure 8msb Byte2: Differential Pressure 8lsb Byte3: CRC Byte4: Temperature 8msb Byte5: Temperature 8lsb Byte6: CRC Byte7: Scale Factor differential pressure 8msb Byte8: Scale Factor differential pressure 8lsb Byte9: CRC After a start continuous measurement commands, the measurement results can be read out. The temperature and scale factor don’t need to be read out (every time). The read sequence can be aborted by a NACK and a STOP condition. 5.3.2 Stop Continuous Measurement Command Command code (Hex) Description Stop continuous measurement 0x3FF9 This command stops the continuous measurement. It powers off the heater and makes the sensor receptive for another command. The Stop command is also required when switching between different continuous measurement commands. When the sensor is in continuous measurement mode, the sensor must be stopped before it can accept another command. The only exception is the soft reset command as described in section 5.3.5. In idle mode the sensor will consume less power. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |