| поискавой системы для электроныых деталей |
|
EB100 датащи(PDF) 2 Page - TE Connectivity Ltd |
|
|
|||||||||||||||||||||||||||||
EB100 датащи(HTML) 2 Page - TE Connectivity Ltd |
|
2 / 4 page ![]() EB100 High Accuracy Miniature Pressure Transducer SENSOR SOLUTIONS ///EB100_en 08/2016 Page 2 STANDARD RANGES Ranges (FS) Pressure Reference Pressure Overload (rated pressure) Burst Pressure (rated pressure) bar psi abs. (type3) 20 300 2 x FS 3 x FS 35 500 2 x FS 3 x FS 70 1K 2 x FS 3 x FS 100 1.5K 2 x FS 3 x FS 200 3K 2 x FS 3 x FS 350 5K 2 x FS 3 x FS PERFORMANCE SPECIFICATIONS (typical values at temperature 23±3°C) PARAMETERS VALUES NOTES Combined Non-Linearity, Hysteresis, and Repeatability ±0.25 %FS 1 Long Term Stability (1 year) ±0.1 %FS Total Error Band (TEB over CTR) ±1 %FS 2 Bandwidth (-3 dB) 120 Hz Isolation resistance @50Vdc 50 MΩ Compensated Temperature Range (CTR) -20 to +125 °C (-4 to+257 F) Operating Temperature Range (OTR) -40 to +125 °C (-40 to +257 F) Storage Temperature -40 to +125 °C (-40 to +257 F) Vibration (20 to 200Hz) 20 g 3 Shock (11ms) 50 g 4 Pressure Cycles (Zero to Full Scale) 1 Million Weight (without cable) 15 grams +21 grams per meter of cable Ingress Protection IP66 Media Compatibility Fluids compatible with 17-4PH, 316 S.S. and FKM Fluoroelastomer Notes 1. Best fit straight line for all pressure ranges except for 200 bar (3 kpsi) = +/-0.35% and 350 bar (5 kpsi) = +/-0.5%. 2. TEB includes all accuracy errors, thermal errors, span and zero tolerances. 3. Per MIL-STD-810C, Procedure 514.2, Figure 514.2-2, Curve L. 4. 1/2 sine per MIL-STD 202F Method 213B condition A. CE compliance IEC 55022 Emissions Class A & B IEC 61000-4-2 Electrostatic Discharge Immunity (2kV contact/2kV air) IEC 61000-4-3 EM Field Immunity (3V/m) IEC 61000-4-4 Electrical Fast Transient Immunity (0.5kV) IEC 61000-4-6 Conducted Immunity (3V) SUPPLY VOLTAGE ELECTRICAL CONNECTION OPTIONS (table 1) Code Supply voltage Signal Code Connection U 8 to 30 V (current < 5 mA) 0.5 – 4.5 V M 1 metre of shielded cable (PFA) P 5 metres of shielded cable (PFA) R 10 metres of shielded cable (PFA) S 1 metre of shielded cable (PFA) fully covered by shrink tube model Raychem DR25 or equivalent |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |