| поискавой системы для электроныых деталей |
|
REG113 датащи(PDF) 10 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
REG113 датащи(HTML) 10 Page - Texas Instruments |
|
10 / 16 page ![]() REG113 10 SBVS031D www.ti.com POWER DISSIPATION The REG113 is available in two different package configura- tions. The ability to remove heat from the die is different for each package type and, therefore, presents different considerations in the printed circuit board (PCB) layout. On the MSOP-8 package, leads 5 through 8 are fused to the lead frame and may be used to improve the thermal performance of the package. The PCB area around the device that is free of other compo- nents moves the heat from the device to the ambient air. Although it is difficult or impossible to quantify all of the variables in a thermal design of this type, performance data for several simplified configurations are shown in Figure 6. In all cases the PCB copper area is bare copper, free of solder resist mask, and not solder plated. All examples are for 1-ounce copper and in the case of the MSOP-8, the copper area is connected to fused leads 5 to 8. See Figure 7 for thermal resistance for varying areas of copper. Using heavier copper can increase the effectiveness in removing the heat from the device. In those examples where there is copper on both sides of the PCB, no connection has been provided between the two sides. The addition of plated through holes will improve the heat sink effectiveness. For large step changes in load current, the REG113 requires a larger voltage drop across it to avoid degraded transient response. The boundary of this transient dropout region is shown as the top line in Figure 5. Values of VIN to VOUT voltage drop above this line insure normal transient response. In the transient dropout region between DC and Transient, transient response recovery time increases. The time required to recover from a load transient is a function of both the magnitude and rate of the step change in load current and the available headroom VIN to VOUT voltage drop. Under worst-case condi- tions (full-scale load change with (VIN – VOUT) voltage drop close to DC dropout levels), the REG113 can take several hundred microseconds to re-enter the specified window of regulation. TRANSIENT RESPONSE The REG113 response to transient line and load conditions improves at lower output voltages. The addition of a capacitor (nominal value 0.47 µF) from the output pin to ground may improve the transient response. In the adjustable version, the addition of a capacitor, CFB (nominal value 10nF), from the output to the adjust pin also improves the transient response. THERMAL PROTECTION Power dissipated within the REG113 can cause the junction temperature to rise, however, the REG113 has thermal shutdown circuitry that protects the regulator from damage. The thermal protection circuitry disables the output when the junction temperature reaches approximately 160 °C, allowing the device to cool. When the junction temperature cools to approximately 140 °C, the output circuitry is again enabled. Depending on various conditions, the thermal protection circuit can cycle on and off. This limits the dissipation of the regulator, but can have an undesirable effect on the load. Any tendency to activate the thermal protection circuit indi- cates excessive power dissipation or an inadequate heat sink. For reliable operation, junction temperature should be limited to 125 °C, maximum. To estimate the margin of safety in a complete design (including heat sink), increase the ambient temperature until the thermal protection is triggered. Use worst-case loads and signal conditions. For good reliability, thermal protection should trigger more than 35 °C above the maximum expected ambient condition of the application. This produces a worst-case junction temperature of 125 °C at the highest expected ambient temperature and worst-case load. The internal protection circuitry of the REG113 is designed to protect against overload conditions and is not intended to replace proper heat sinking. Continuously running the REG113 into thermal shutdown will degrade reliability. 3.0 2.5 2.0 1.5 1.0 0.5 0 MAXIMUM POWER DISSIPATION vs TEMPERATURE –50 –25 0 25 50 75 100 125 Ambient Temperature ( °C) Condition 1 Condition 2 Condition 3 CONDITION PACKAGE PCB AREA θ JA 1 MSOP-8 1 sq. in. Cu, 1 Side 71 2 MSOP-8 0.25 sq. in. Cu, 1 Side 90 3 SOT-23-8 None 200 FIGURE 6. Maximum Power Dissipation versus Ambient Tem- perature for the Various Packages and PCB Heat Sink Configurations. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |